Development and Evaluation of PANI-PecPaper Strip Sensor for Detection of Total Plate Count in Milk and Milk Products DOI

Shreya Saha,

Mohit Singh,

Maharshi Prajapathi

и другие.

Food Control, Год журнала: 2025, Номер unknown, С. 111397 - 111397

Опубликована: Апрель 1, 2025

Язык: Английский

Removal of protonic doping from PEDOT:PSS by weak base for improving aluminum solid electrolytic capacitor performance DOI Creative Commons
Piao Luo, Kai Zhang,

Nanjie Wu

и другие.

RSC Advances, Год журнала: 2025, Номер 15(11), С. 8719 - 8728

Опубликована: Янв. 1, 2025

It was found that bases may modulate doping levels by removing proton and improve carrier mobility of PEDOT:PSS.

Язык: Английский

Процитировано

0

Tissue-adhesive, silk-based conductive hydrogel with high stretchable, transparent, healable and degradable properties for real-time, precise monitoring of tissue motions and electrocardiogram under sweaty condition DOI
Jiajia Li,

Qinan Ban,

Min Xu

и другие.

Journal of Colloid and Interface Science, Год журнала: 2025, Номер unknown, С. 137455 - 137455

Опубликована: Март 1, 2025

Язык: Английский

Процитировано

0

Isolated PEDOT-based organic-ionic-hydrogel as the sensitive portable electroanalytical platform for paracetamol determination DOI

Wang Sun,

Guorong Sun,

Junyan Liu

и другие.

Chemical Engineering Journal, Год журнала: 2025, Номер unknown, С. 162023 - 162023

Опубликована: Март 1, 2025

Язык: Английский

Процитировано

0

Transparent, metal-free PEDOT:PSS neural interfaces for simultaneous recording of low-noise electrophysiology and artifact-free two-photon imaging DOI Creative Commons

Hyun Woo Kim,

Jiwon Kim, Jong Youl Kim

и другие.

Nature Communications, Год журнала: 2025, Номер 16(1)

Опубликована: Апрель 29, 2025

Simultaneous two-photon imaging and electrophysiological recordings offer considerable potential for advancing neurological research therapies. However, traditional metal-based neural interfaces suffer from photoelectric artifacts, while existing transparent implants rely on opaque interconnect lines to address conductivity limitations. Herein, we developed an optically poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) electrode array with electrodes lines. Through a formamide, phosphoric acid, ethylene glycol treatment, the metal-free PEDOT:PSS achieved impedance of 45.8 kΩ (at 1 kHz) even 20 × µm² size. This advanced performance surpasses previous facilitates precise recordings, including extracellular action potentials low-noise local field potentials. In vivo experiments demonstrated artifact-free reliable signal acquisition, biocompatibility tests confirmed negligible cytotoxicity or immune responses. The provides robust platform recording bioimaging, representing advancement in interface technology integrated optical modalities.

Язык: Английский

Процитировано

0

Development and Evaluation of PANI-PecPaper Strip Sensor for Detection of Total Plate Count in Milk and Milk Products DOI

Shreya Saha,

Mohit Singh,

Maharshi Prajapathi

и другие.

Food Control, Год журнала: 2025, Номер unknown, С. 111397 - 111397

Опубликована: Апрель 1, 2025

Язык: Английский

Процитировано

0