MOF-199-based coatings as SPME fiber for measurement of volatile organic compounds in air samples: Optimization of in situ deposition parameters DOI
Anara Omarova, Nassiba Baimatova, Hossein Kazemian

и другие.

Microchemical Journal, Год журнала: 2022, Номер 185, С. 108263 - 108263

Опубликована: Дек. 5, 2022

Язык: Английский

Recent advances in the electrochemical applications of Ni-based metal organic frameworks (Ni-MOFs) and their derivatives DOI
Xuezhang Liu,

Hanping Yang,

Yingyao Diao

и другие.

Chemosphere, Год журнала: 2022, Номер 307, С. 135729 - 135729

Опубликована: Авг. 2, 2022

Язык: Английский

Процитировано

71

Electrochemical-Based Sensing Platforms for Detection of Glucose and H2O2 by Porous Metal–Organic Frameworks: A Review of Status and Prospects DOI Creative Commons
Hessamaddin Sohrabi,

Fatemeh Maleki,

Pegah Khaaki

и другие.

Biosensors, Год журнала: 2023, Номер 13(3), С. 347 - 347

Опубликована: Март 4, 2023

Establishing enzyme-free sensing assays with great selectivity and sensitivity for glucose H2O2 detection has been highly required in biological science. In particular, the exploitation of nanomaterials by using noble metals high conductivity surface area widely investigated to act as selective catalytic agents molecular recognition platforms. Several approaches a straightforward, speedy, selective, sensitive were requested. This paper reviews current progress electrochemical metal–organic frameworks (MOFs) recognition. We have reviewed latest in-place priorities including straightforward procedure manipulation, sensitivity, varied linear range, economic prospects. The mentioned apply systems through rapid time that enables real-time profitable fields, obstacles associated sample preparation tool expense can be solved applying these means. Some parameters, impedance, intensity, potential difference measurement methods permitted low limit detections (LODs) noticeable durations agricultural, water, foodstuff samples levels H2O2.

Язык: Английский

Процитировано

56

A free enzyme electrochemical glucose sensor using an Integrated display to CeO2 NPs/Ni MOF-based sensor to highly sensitive Determination of glucose in sweat DOI

Amirali Atefi,

Sara Moradi,

Foad Salehnia

и другие.

Microchemical Journal, Год журнала: 2025, Номер unknown, С. 112809 - 112809

Опубликована: Янв. 1, 2025

Язык: Английский

Процитировано

3

Transformative chelation pathways unveiling NiMOF-LDH hybrids on MgO for high-efficiency photocatalysis DOI Creative Commons
Mohammad Aadil, Ananda Repycha Safira,

Mohammad Alkaseem

и другие.

Journal of Materials Chemistry A, Год журнала: 2025, Номер unknown

Опубликована: Янв. 1, 2025

Tailoring NiMOF growth via EDTA sequencing for enhanced photocatalysis; controlled addition directed or NiMg LDH formation on MgO, where exhibited superior crystallinity, stability, and photocatalytic efficiency.

Язык: Английский

Процитировано

2

Nickel-based catalysts for non-enzymatic electrochemical sensing of glucose: A review DOI Creative Commons
Filippo Franceschini, Irene Taurino

Physics in Medicine, Год журнала: 2022, Номер 14, С. 100054 - 100054

Опубликована: Сен. 26, 2022

Nickel-based catalysts are currently the subject of intensive study in search for novel electrode materials non-enzymatic glucose sensing. Their strong activity towards electrooxidation and intrinsic resistance to chloride poisoning makes these ideal candidates development affordable stable sensors. In this review, mechanism at Ni electrodes is described, clarifying effect different phases on their catalytic activity. Moreover, a brief background provided, supplemented by computational studies. Furthermore, article details most intriguing compounds (selenides, sulfides, nitrates) analytical performance respective Additional focus points work multimetallic nanosystems where component, growing field conductive metal organic frameworks with centers. This review will be beneficial researchers who aim delving deeper into potential Ni-based

Язык: Английский

Процитировано

44

Metal-organic frameworks (MOFs) structural properties and electrochemical detection capability for cancer biomarkers DOI
Brij Mohan, Diksha Dhiman,

Virender Virender

и другие.

Microchemical Journal, Год журнала: 2023, Номер 193, С. 108956 - 108956

Опубликована: Июнь 10, 2023

Язык: Английский

Процитировано

37

Recent Progress in MOF-Based Electrochemical Sensors for Non-Enzymatic Glucose Detection DOI Creative Commons
Ziteng Li, Wen Zeng, Yanqiong Li

и другие.

Molecules, Год журнала: 2023, Номер 28(13), С. 4891 - 4891

Опубликована: Июнь 21, 2023

In recent years, substantial advancements have been made in the development of enzyme-free glucose sensors utilizing pristine metal-organic frameworks (MOFs) and their combinations. This paper provides a comprehensive exploration various MOF-based sensors, encompassing monometallic MOF as well multi-metal These approaches demonstrate improved detection capabilities, facilitated by augmented surface area availability active sites within structures. Furthermore, delves into application complexes derivatives sensing. Derivatives incorporating carbon or metal components, such cloth synthesis, rGO-MOF composites, core–shell structures noble metals, exhibit enhanced electrochemical performance. Additionally, integration MOFs with foams biomolecules, porphyrins, enhances electrocatalytic properties for detection. Finally, this concludes an outlook on future prospects sensors.

Язык: Английский

Процитировано

25

Catalytic Modification of Porous Two-Dimensional Ni-MOFs on Portable Electrochemical Paper-Based Sensors for Glucose and Hydrogen Peroxide Detection DOI Creative Commons
Ya Yang, Wenhui Ji,

Yutao Yin

и другие.

Biosensors, Год журнала: 2023, Номер 13(5), С. 508 - 508

Опубликована: Апрель 28, 2023

Rapid and accurate detection of changes in glucose (Glu) hydrogen peroxide (H2O2) concentrations is essential for the predictive diagnosis diseases. Electrochemical biosensors exhibiting high sensitivity, reliable selectivity, rapid response provide an advantageous promising solution. A porous two-dimensional conductive metal-organic framework (cMOF), Ni-HHTP (HHTP = 2,3,6,7,10,11-hexahydroxytriphenylene), was prepared by using a one-pot method. Subsequently, it employed to construct enzyme-free paper-based electrochemical sensors applying mass-producing screen-printing inkjet-printing techniques. These effectively determined Glu H2O2 concentrations, achieving low limits 1.30 μM 2.13 μM, sensitivities 5573.21 μA μM-1 cm-2 179.85 cm-2, respectively. More importantly, Ni-HHTP-based showed ability analyze real biological samples successfully distinguishing human serum from artificial sweat samples. This work provides new perspective use cMOFs field sensing, highlighting their potential future applications design development multifunctional high-performance flexible electronic sensors.

Язык: Английский

Процитировано

24

Pyrene Derivative Incorporated Ni MOF as an Enzyme Mimic for Noninvasive Salivary Glucose Detection Toward Diagnosis of Diabetes Mellitus DOI
Mallikarjuna Swamy Shabanur Matada,

Guru Prasad Kuppuswamy,

Sheethal Sasi

и другие.

ACS Applied Materials & Interfaces, Год журнала: 2024, Номер 16(14), С. 17219 - 17231

Опубликована: Апрель 2, 2024

Herein, we demonstrate the detection of glucose in a noninvasive and nonenzymatic manner by utilizing an extended gate field-effect transistor (EGFET) based on organic molecule pyrene phosphonic acid (PyP4OH8) incorporated nickel metal–organic framework (NiOM-MOF). The prepared electrode responds selectively to instead sucrose, fructose, maltose, ascorbic acid, uric 1× phosphate buffer saline solution. Also, scanning Kelvin probe system, sensing electrode's work function (Φ) is measured validate glucose-sensing mechanism. sensitivity, range, response time, limit detection, quantification are determined be 24.5 μA mM–1 cm–2, 20 μM 10 mM, less than 5 s, 2.73 μM, 8.27 respectively. Most interestingly, developed follows Michaelis–Menten kinetics, calculated rate constant (km) 0.07 mM indicates higher affinity NiOM-MOF toward glucose. real-time analysis has revealed that sensitive detect real human saliva, it can alternative device for Overall, outcomes EGFET studies electrodes well-suited expeditious levels saliva.

Язык: Английский

Процитировано

11

Fe2W18Fe4@MOF-Ni-100 nanocomposite: Insights into synthesis and application as a promising material towards the electrocatalytic water oxidation DOI
Mohammad Ali Rezvani,

Hadi Hassani Ardeshiri,

Hossein Ghafuri

и другие.

Advanced Powder Technology, Год журнала: 2024, Номер 35(4), С. 104380 - 104380

Опубликована: Март 9, 2024

Язык: Английский

Процитировано

10