Effect of Crevice Size on Crevice Corrosion of N80 Carbon Steel in CO2-Saturated NaCl-HAc Solution DOI Open Access
Pengfei Hu, Guangyi Cai, Yizhou Li

и другие.

Materials, Год журнала: 2024, Номер 17(16), С. 4078 - 4078

Опубликована: Авг. 16, 2024

The effect of crevice size on the corrosion N80 carbon steel was investigated by electrochemical measurements and surface analysis in a CO2-saturated NaCl-HAc solution. exhibits high susceptibility to this environment, which can be initiated immediately without an induction period for specimens with sizes 100 μm, 300 500 μm. Typically, solutions become more acidic during corrosion; however, study, solution became alkaline, resulting galvanic between inner outer surfaces leading severe corrosion. pH levels μm are similar, but both notably higher than that specimen size. As result, there is no significant difference phenomenon sizes, it

Язык: Английский

A Combination of Laboratory Testing, RCE, and Corrosion Loop for Inhibitor Selection DOI Creative Commons
Gustavo Luis Bianchi,

Verónica Acosta,

Carlos Javier Seijas

и другие.

Applied Sciences, Год журнала: 2023, Номер 13(7), С. 4586 - 4586

Опубликована: Апрель 4, 2023

Corrosion inhibitors are evaluated in the oil industry with electrochemical tests of resistance to linear polarization rotating cylinders following ASTM G170 and NACE 3T199 standards. With these tests, we can determine corrosion rate (CR) efficiency inhibitors. In this work, a test protocol used by hydrocarbon-producing companies for testing was used. This consists 1045 carbon steel working electrode solution composed 9.62% NaCl, 0.45% CaCl2, 0.19% MgCl2, 89.74% H2O, at temperature 65 °C saturated CO2. Each inhibitor tested subjected series 6000-4000-2000-4000-6000 rpm using cylinder electrodes (RCEs). These studies were carried out evaluate ability prevent presence centrifugal force. our opinion, does not provide engineers enough information be as predictive tool, since what is obtained CR very short time. document proposes use two more appropriate methodologies, (RCE) flow loop (FL), performance inhibitor. For FL, selected 1.2 m/s, same that fluids have company pipelines installed Neuquén, Argentina. Firstly, according company’s protocol, required an greater than or equal 90% RCE tests; therefore, meet requirements FL test. Unlike test, represents experimental conditions laboratory closest reality, evaluation gas industry. several problems involving corrosion, erosion, abrasion, biphasic fluids, time it takes become effective, duration its effectiveness.

Язык: Английский

Процитировано

1

Research on Novel High-Temperature Oilfield Water-Based Annulus Protection Fluid DOI
Kai Xie, Tao Ye, Chen Wei

и другие.

Опубликована: Янв. 1, 2024

Язык: Английский

Процитировано

0

A Study on the Problem of AC Corrosion of Power Umbilical Cables Caused by Electromagnetic Induction Phenomena DOI Creative Commons

Pengjin Shao,

Haijun Li, Pan Pan

и другие.

Energies, Год журнала: 2024, Номер 17(14), С. 3588 - 3588

Опубликована: Июль 21, 2024

During the normal laying and operation of a three-core umbilical cable, AC current can easily lead to electrochemical corrosion on outer surface steel tube. To explore mechanism factors affecting this paper optimizes internal induced potential calculation method for cables. It analyzes changes in characteristics explores variations density under different conditions. The research results show that by optimizing induction cable’s pipe, electromagnetic significance smallest repeating unit, pipe’s exhibited cyclic change. peak part is most likely experience corrosion. Additionally, reducing radius insulation aperture pipe improving conductivity seawater will increase aperture, thereby increasing risk As cable pitch frequency increase, pores also rise.

Язык: Английский

Процитировано

0

Failure Analysis and Experiment of Shale Gas Gathering Pipeline DOI

Yong Chen,

Taiwei Luo,

Dongying Meng

и другие.

Transactions of the Indian Institute of Metals, Год журнала: 2024, Номер 77(11), С. 3641 - 3652

Опубликована: Авг. 2, 2024

Язык: Английский

Процитировано

0

Effect of Crevice Size on Crevice Corrosion of N80 Carbon Steel in CO2-Saturated NaCl-HAc Solution DOI Open Access
Pengfei Hu, Guangyi Cai, Yizhou Li

и другие.

Materials, Год журнала: 2024, Номер 17(16), С. 4078 - 4078

Опубликована: Авг. 16, 2024

The effect of crevice size on the corrosion N80 carbon steel was investigated by electrochemical measurements and surface analysis in a CO2-saturated NaCl-HAc solution. exhibits high susceptibility to this environment, which can be initiated immediately without an induction period for specimens with sizes 100 μm, 300 500 μm. Typically, solutions become more acidic during corrosion; however, study, solution became alkaline, resulting galvanic between inner outer surfaces leading severe corrosion. pH levels μm are similar, but both notably higher than that specimen size. As result, there is no significant difference phenomenon sizes, it

Язык: Английский

Процитировано

0