The Role of NT-proBNP Levels in the Diagnosis of Hypertensive Heart Disease
Diagnostics,
Год журнала:
2025,
Номер
15(1), С. 113 - 113
Опубликована: Янв. 6, 2025
Hypertension
is
a
major
risk
factor
of
various
cardiac
complications,
including
hypertensive
heart
disease
(HHD).
This
condition
can
lead
to
number
structural
and
functional
changes
in
the
heart,
such
as
left
ventricular
hypertrophy,
diastolic
dysfunction,
and,
eventually,
systolic
dysfunction.
In
management
disease,
early
diagnosis
appropriate
treatment
are
crucial
for
preventing
progression
congestive
failure.
One
potential
diagnostic
marker
that
has
gained
attention
recent
years
N-terminal
pro-brain
natriuretic
peptide
(NT-proBNP).
The
peptides,
brain
(BNP)
its
inactive
fragment,
secreted
by
myocardium
response
increased
wall
stress
volume
overload.
patients
with
NT-proBNP
levels
may
reflect
occurring
result
chronic
pressure
Several
studies
have
investigated
utility
disease.
be
useful
adjunct
particularly
assessment
dysfunction
hypertrophy.
review
paper
explores
role
Язык: Английский
Integrative bioinformatic analysis of prognostic biomarkers in heart failure: Insights from clinical trials
European Journal of Clinical Investigation,
Год журнала:
2025,
Номер
unknown
Опубликована: Фев. 16, 2025
Abstract
Background
Heart
failure
(HF)
remains
a
major
cause
of
morbidity
and
mortality
worldwide.
Therefore,
there
is
need
to
identify
robust
biomarkers
improve
early
diagnosis,
stratify
disease
severity
predict
outcomes.
Biomarkers
such
as
galectin‐3
(Gal‐3),
TIMP‐1,
BNP,
NT‐proBNP,
CysC,
CA125,
ST2
MMP9
have
shown
the
potential
reflect
pathophysiology
HF.
Despite
their
clinical
potential,
integration
into
routine
practice
still
limited.
The
use
bioinformatics
may
help
uncover
critical
associations
between
these
progression
HF,
providing
opportunities
for
personalized
management.
Methods
Following
PRISMA
guidelines,
systematic
review
studies
was
performed
using
databases
with
time
constraints.
proteins
associated
HF
were
identified
diagnostic
prognostic
roles
analysed.
Results
study
emphasizes
that
(Gal‐3)
TIMP‐1
serve
key
indicators
fibrosis
inflammation,
while
BNP
NT‐proBNP
are
reliable
markers
cardiac
stress.
Cystatin
C
(CysC)
reflects
renal
dysfunction,
CA125
correlates
strongly
venous
congestion.
In
addition,
provide
valuable
insights
inflammation
tissue
remodelling
processes.
These
consistently
elevated
in
patients
emphasizing
role
detecting
systemic
manifestations
disease.
Conclusion
Our
results
emphasize
importance
including
Gal‐3,
diagnosis
treatment
Their
upregulation
complex
pathophysiological
processes
supports
setting
accuracy,
precision
therapeutic
strategies.
Язык: Английский
Recent advances in MOF-modified electrochemical sensor for point-of-care detecting cardiac biomarkers
TrAC Trends in Analytical Chemistry,
Год журнала:
2025,
Номер
unknown, С. 118277 - 118277
Опубликована: Апрель 1, 2025
Язык: Английский
The CRISPR/Cas13a-assisted electrochemiluminescence sensing device combined with entropy-driven and hybrid chain reaction nucleic acid amplification techniques for ultra-sensitive analysis of brain natriuretic peptide
Talanta,
Год журнала:
2025,
Номер
unknown, С. 128310 - 128310
Опубликована: Май 1, 2025
Язык: Английский
Enhanced Electrochemiluminescence Sensing of Brain Natriuretic Peptide (BNP) using Copper Nanocluster and Luminol-H2O2 based System in Heart Failure Diagnosis
B. K. Arathy,
Merin K. Abraham,
Geneva Indongo
и другие.
Talanta,
Год журнала:
2025,
Номер
295, С. 128362 - 128362
Опубликована: Май 21, 2025
Язык: Английский
Prognostic Utility of N-terminal Pro-B-type Natriuretic Peptide (NT-proBNP) for Predicting Hospital Readmissions in Patients With Heart Failure: A Systematic Review of Clinical Evidence
Cureus,
Год журнала:
2025,
Номер
unknown
Опубликована: Июнь 2, 2025
Язык: Английский
DISPOSITIVOS MÉDICOS CONECTADOS. AVANCES EN MONITOREO Y DIAGNÓSTICO
New Trends in Qualitative Research,
Год журнала:
2024,
Номер
20(3), С. e1053 - e1053
Опубликована: Авг. 26, 2024
Introducción:
Este
estudio
examina
la
revolución
tecnológica
en
el
ámbito
de
los
dispositivos
médicos
conectados,
que
están
redefiniendo
monitoreo,
diagnóstico
y
tratamiento
enfermedades.
Se
analiza
cómo
integración
tecnologías
avanzadas
está
impulsando
atención
médica
personalizada
a
distancia.
Objetivos:
Evaluar
avances
conectados
su
impacto
mejora
del
monitoreo
investiga
estas
cambiando
dinámica
cuáles
son
desafíos
oportunidades
asociados.
Metodología:
utiliza
un
enfoque
cualitativo,
vinculando
preguntas
investigación
con
teorías
resultados.
El
se
basa
análisis
wearables
sistemas
implantables,
combinando
revisión
literatura
entrevistas
expertos
datos.
metodológico
permite
una
comprensión
profunda
interacción
entre
tecnología
práctica
médica.
Resultados:
Los
hallazgos
muestran
ofrecen
significativas
ventajas
términos
precisión
eficiencia,
permitiendo
seguimiento
tiempo
real
mejor
toma
decisiones
clínicas.
identifican
retos
técnicos,
éticos
regulatorios,
pero
también
destacan
soluciones
innovadoras
para
superarlos.
Conclusiones:
La
subraya
importancia
cualitativo
conectados.
resultados
enfatizan
necesidad
marco
robusto
evaluar
tanto
tecnológicos
como
contribuye
transformando
médica,
enfatizando
abordajes
integrados
multidisciplinarios
maximizar
sus
beneficios
minimizar
riesgos.
Metal-Organic Frameworks: Performance, Fabrication, and Applications in Biosensors
Transactions on Materials Biotechnology and Life Sciences,
Год журнала:
2024,
Номер
7, С. 289 - 292
Опубликована: Дек. 24, 2024
Biosensors
serve
as
key
detection
tools
in
many
fields,
such
clinical
diagnosis,
environmental
monitoring
and
food
safety.
Although
breakthroughs
have
been
achieved
the
field
of
sensor
technology,
related
issues
sensitivity,
specificity
stability
remain
unresolved.
Recent
academic
research
has
highlighted
significant
prospects
metal-organic
frameworks
(MOFs)
potential
solutions
to
these
problems.
The
MOFs,
which
are
composed
organic
ligands
metal
ions,
high
surface
area,
adjustable
pore
size
excellent
chemical
versatility.
By
optimizing
characteristics,
sensitivity
selectivity
biosensors
improved,
thereby
improving
their
performance.
This
study
analyzes
extensive
on
MOF-based
biosensors.
paper
emphasizes
synthesis
methods,
functionalization
strategies,
applications.
Specifically,
application
here
is
mainly
biomarkers
cancer
cardiovascular
diseases.
role
MOFs-based
cell
tissue
imaging
discussed
well.
goal
this
explain
latest
results
define
areas
exploration
for
subsequent
scientific
works.
work
would
contribute
improve
biosensing
technology.
Язык: Английский