BCLA CLEAR Presbyopia: Management with contact lenses and spectacles
Contact Lens and Anterior Eye,
Год журнала:
2024,
Номер
47(4), С. 102158 - 102158
Опубликована: Апрель 16, 2024
This
paper
seeks
to
outline
the
history,
market
situation,
clinical
management
and
product
performance
related
correction
of
presbyopia
with
both
contact
lenses
spectacles.
The
history
development
various
optical
forms
presbyopic
are
reviewed,
an
overview
is
presented
current
status
Clinical
considerations
in
fitting
aftercare
lens
spectacle
wearers
presented,
general
recommendations
for
best
practice.
Current
options
include
soft
simultaneous,
rigid
translating
simultaneous
designs,
addition
monovision.
Spectacle
single
vision
lenses,
bifocal
a
range
progressive
lenses.
comparative
presented.
With
significant
proportion
global
population
now
being
presbyopic,
this
particularly
timely
designed
act
as
guide
researchers,
industry
eyecare
practitioners
alike.
Язык: Английский
BCLA CLEAR Presbyopia: Epidemiology and impact
Contact Lens and Anterior Eye,
Год журнала:
2024,
Номер
47(4), С. 102157 - 102157
Опубликована: Апрель 9, 2024
The
global
all-ages
prevalence
of
epidemiologically-measured
'functional'
presbyopia
was
estimated
at
24.9%
in
2015,
affecting
1.8
billion
people.
This
projected
to
stabilise
24.1%
2030
due
increasing
myopia,
but
affect
more
people
(2.1
billion)
population
dynamics.
Factors
the
include
age,
geographic
location,
urban
versus
rural
sex,
and,
a
lesser
extent,
socioeconomic
status,
literacy
and
education,
health
inequality.
Risk
factors
for
early
onset
included
environmental
factors,
nutrition,
near
demands,
refractive
error,
accommodative
dysfunction,
medications,
certain
conditions
sleep.
Presbyopia
found
impact
on
quality-of-life,
particular
quality
vision,
labour
force
participation,
work
productivity
financial
burden,
mental
health,
social
wellbeing
physical
health.
Current
understanding
makes
it
clear
that
is
very
common
age-related
condition
has
significant
impacts
both
patient-reported
outcome
measures
economics.
However,
there
are
complexities
defining
epidemiological
studies.
Standardisation
definitions
will
assist
future
synthesis,
pattern
analysis
sense-making
between
Язык: Английский
Simulation of daily soft multifocal contact lenses using SimVis Gekko: from in-vitro and computational characterization to clinical validation
Scientific Reports,
Год журнала:
2024,
Номер
14(1)
Опубликована: Апрель 13, 2024
Abstract
Multifocal
contact
lenses
(MCLs)
are
one
of
the
solutions
to
correct
presbyopia,
but
their
adoption
is
not
widespread.
To
address
this
situation,
visual
simulators
can
be
used
refine
adaptation
process.
This
study
aims
obtain
accurate
simulations
for
a
simulator
(SimVis
Gekko;
2EyesVision)
daily
soft
MCL
designs
from
four
manufacturers.
In-vitro
characterization
these
MCLs—several
powers
and
additions-
was
obtained
using
NIMO
TR-1504.
From
averaged
relative
power
profiles
across
powers,
phase
maps
were
reconstructed
Through-Focus
Visual
Strehl
metric
calculated
each
design.
The
SimVis
Gekko
simulation
corresponding
design
computationally
bench-validated.
Finally,
clinically
validated
involving
presbyopic
patients.
clinical
validation
results
show
good
agreement
between
real
MCLs
through-focus
acuity
(TF-VA)
curves
VA
at
three
distances.
All
showed
partial
correlation
higher
than
0.90
Root
Mean
Square
Error
below
0.07
logMAR
TF-VA
Real
subjects.
validity
approach
in-vitro
measurements
confirmed
in
study,
opening
possibility
accelerate
MCLs.
Язык: Английский
Vision corrections used by presbyopic orienteers
Optometry and Vision Science,
Год журнала:
2024,
Номер
unknown
Опубликована: Окт. 29, 2024
SIGNIFICANCE
Evaluating
the
visual
challenges
and
refractive
correction
solutions
of
presbyopic
orienteers
identifies
features
relevance
to
optometric
management
needs
active
presbyopes.
PURPOSE
Orienteering
is
a
unique
sport
requiring
clarity
at
range
viewing
distances
has
high
proportion
participants.
This
study
evaluates
vision
corrections
used
by
orienteers,
specifically
aiming
characterize
prevalence
different
options
explore
strengths
limitations
solutions.
METHODS
Orienteers
40
years
or
older
completed
an
online
questionnaire
consisting
multiple-choice
questions
covering
personal
demographics,
orienteering
participation,
worn
in
everyday
life
for
orienteering.
Free-text
asked
further
information
about
advice
received
from
eye
care
practitioners
were
analyzed
using
content
analysis.
RESULTS
There
469
respondents
(195
women,
274
men;
median
age
category,
55
59
years).
For
187
people
without
distance
correction,
most
frequent
“off
shelf”
reading
spectacles
(n
=
95)
use
compass
magnifier
24),
277
with
they
progressive
addition
96)
monovision
contact
lenses
63).
The
main
faced
seeing
map
detail,
lens
obstruction
fogging
rain,
difficulty
low
light
daytime.
An
ideal
needed
provide
both
terrain.
No
type
consistently
addressed
all
challenges.
valued
personalized
discussion
address
their
needs.
CONCLUSIONS
Optimal
are
individual,
but
higher
additions
clarify
avoid
obstruction,
additional
light,
that
clear
while
avoiding
add
blurring
ground
orienteer's
feet
should
be
considered.
Personalized
necessary
optimize
Язык: Английский
Simulation of daily soft multifocal contact lenses using SimVis Gekko: from in-vitro and computational characterization to clinical validation
Research Square (Research Square),
Год журнала:
2023,
Номер
unknown
Опубликована: Май 25, 2023
Abstract
Multifocal
contact
lenses
(MCLs)
are
one
of
the
solutions
to
correct
presbyopia,
but
their
adoption
is
not
widespread
due
factors
such
as
discomfort,
lack
awareness,
a
lengthy
fitting
process
and/or
unexpected
visual
performance.
To
address
this
situation,
simulators
can
be
used
aid
in
refining
adaptation
process.
This
study
aims
obtain
accurate
simulations
for
novel
simulator
(SimVis
Gekko;
2EyesVision,
Spain)
various
daily
commercial
soft
MCL
designs
from
four
different
manufacturers:
Dailies
Total1
(Alcon),
MyDay
(Coopervision),
1Day
Acuvue
Moist
(Johnson
&
Johnson)
and
Biotrue
ONEday
(Bausch
+
Lomb).
In-vitro
characterization
these
MCLSs
-for
several
distance
powers
additions-
was
obtained
using
NIMO
TR-1504
instrument
(Lambda-X,
Belgium).
From
averaged
relative
power
profiles
across
powers,
phase
maps
were
reconstructed
Through-Focus
Visual
Strehl
(TFVS)
metric
calculated
each
design
considering
optical
diameters.
The
SimVis
Gekko
simulation
corresponding
pupil
diameter
computationally
validated
on
bench.
Finally,
clinically
pilot
involving
presbyopic
patients
with
refractive
errors
additions.
results
clinical
validation
show
good
agreement
between
real
MCLs
(for
all
designs)
when
measuring
through-focus
acuity
(TFVA)
curves
VA
at
three
distances.
All
showed
partial
correlation
(r
xy,z
)
higher
than
0.90
Root
Mean
Square
Error
(RMSE)
below
0.07
logMAR
TFVA
Real
subjects.
validity
approach
experimental
measurements
Nimo
therefore
confirmed
by
study,
what
opens
possibility
assist
speed
up
MCLs.
Язык: Английский
Standing on the shoulders of giants: The evolution of dry eye disease
Contact Lens and Anterior Eye,
Год журнала:
2024,
Номер
unknown, С. 102318 - 102318
Опубликована: Окт. 1, 2024
Язык: Английский
CPD: BCLA CLEAR Presbyopia
Optician,
Год журнала:
2024,
Номер
270(6983), С. 22 - 27
Опубликована: Ноя. 29, 2024
Neil
Retallic
presents
the
inaugural
article
in
our
new
series
disseminating
landmark
BCLA
CLEAR
Presbyopia
publications
Язык: Английский
Crossing the presbyopia chasm
Meredith Jansen Bishop,
Kurt Moody,
Drew Hansen
и другие.
Optician,
Год журнала:
2023,
Номер
267(6904), С. 19 - 24
Опубликована: Май 26, 2023
Dr
Meredith
Bishop,
Kurt
Moody,
Drew
Hansen
and
Natalie
Ambrose
share
the
results
of
an
in-practice
assessment
undertaken
with
a
large
group
eye
care
professionals
that
looked
at
transition
from
adopting
new
technology
multifocal
contact
lenses
translating
it
into
everyday
practice
fitting
behaviour
Язык: Английский
CPD: It’s good to talk about contact lenses
Optician,
Год журнала:
2022,
Номер
266(6879), С. 19 - 19
Опубликована: Ноя. 18, 2022
In
the
first
of
an
occasional
series
designed
to
provide
a
resource
help
with
training
support
staff,
Neil
Retallic
discusses
many
and
various
ways
contact
lenses
can
be
discussed
patients
in
practice
(C104122,
suitable
for
logging
as
one
provider-led
distance
learning
CPD
point
optometrists
dispensing
opticians)
Язык: Английский