The Contribution of the Pore Size of Titanium DC (Direct Current) Sputtered Condensation Polymer Materials to Electromagnetic Interruption and Thermal Properties DOI Open Access

Hye-Ree Han

Coatings, Год журнала: 2023, Номер 13(10), С. 1756 - 1756

Опубликована: Окт. 11, 2023

Using special materials has been in the spotlight, along with their multifunctional demands, research on electromagnetic interruption, thermal characteristics, biosignal sensors, secondary batteries, etc. In this study, titanium was sputtered into a condensation polymer material and considered depth terms of properties, infrared blocking, As result observing wave shielding effect, wavelength value decreased from 168.0 to 42.7 64.0 when DC film samples were placed front source. The significantly reduced electrical resistance compared untreated samples. addition, IR transmittances specimens specimens. When only cross-section treated sputtering surface directed toward irradiator, permeability 64.3 0.0%. After taking an image, ΔH, ΔV, ΔS, ΔY, ΔCr, ΔCb values calculated. It is believed that polyamide produced study can be used for high-functional protective clothing, sensors by applying stealth functions.

Язык: Английский

Tratamento de fraturas blow-out por técnica transsinusal e uso de Palafita DOI Creative Commons
Lidylara Lacerda Araújo Carvalho, Daniel Alves,

Gilberto Fenelon das Neves

и другие.

Caderno Pedagógico, Год журнала: 2025, Номер 22(1), С. e13608 - e13608

Опубликована: Янв. 22, 2025

Traumas na região da órbita podem gerar uma fratura orbital isolada ou associada aos ossos adjacentes. Dentre as possibilidades de tratamento para fraturas do assoalho existem vários acessos cirúrgicos e materiais reconstrução como enxertos cartilagem costal calota craniana, polietileno poroso, implantes reabsorvíveis, malha titânio. O objetivo deste trabalho é apresentar alternativa acesso transsinusal (mais estético se comparado diretos em pele) através um dispositivo intitulado Palafita. Trata-se relato série casos, com delineamento descritivo, sem grupo controle, caráter narrativo reflexivo, cujos dados são provenientes prática clínica. Em todos os casos relatados neste estudo, pacientes evoluíram reversão dos sinais sintomas ocasionados pelo trauma após a cirurgia, especial atenção à enoftalmia, que o grande desafio correção muitos cirurgiões. A técnica Palafita mostra mais indicada onde busca evitar cicatriz, especial, há quantidade conteúdo herniado seio maxilar, permite sua recuperação órbita.

Процитировано

1

Efficacy of 3D-printed patient specific implant for orbital wall fracture repair in a series of 40 patients DOI Creative Commons

Min Kyu Yang,

Seong Jung Ha,

Gye Jung Kim

и другие.

Scientific Reports, Год журнала: 2025, Номер 15(1)

Опубликована: Фев. 3, 2025

Язык: Английский

Процитировано

1

Comparison of patient specific implant reconstruction vs conventional titanium mesh reconstruction of orbital fractures using a novel method DOI
Andrei Krasovsky, Ahmad Hija, Nidal Zeineh

и другие.

Journal of Cranio-Maxillofacial Surgery, Год журнала: 2024, Номер 52(4), С. 491 - 502

Опубликована: Фев. 5, 2024

Язык: Английский

Процитировано

3

Personalized Medicine in Orbital Surgery DOI

Alexander R. Engelmann,

Shannath L. Merbs

Current Surgery Reports, Год журнала: 2024, Номер 12(10), С. 371 - 378

Опубликована: Авг. 7, 2024

Язык: Английский

Процитировано

0

The Contribution of the Pore Size of Titanium DC (Direct Current) Sputtered Condensation Polymer Materials to Electromagnetic Interruption and Thermal Properties DOI Open Access

Hye-Ree Han

Coatings, Год журнала: 2023, Номер 13(10), С. 1756 - 1756

Опубликована: Окт. 11, 2023

Using special materials has been in the spotlight, along with their multifunctional demands, research on electromagnetic interruption, thermal characteristics, biosignal sensors, secondary batteries, etc. In this study, titanium was sputtered into a condensation polymer material and considered depth terms of properties, infrared blocking, As result observing wave shielding effect, wavelength value decreased from 168.0 to 42.7 64.0 when DC film samples were placed front source. The significantly reduced electrical resistance compared untreated samples. addition, IR transmittances specimens specimens. When only cross-section treated sputtering surface directed toward irradiator, permeability 64.3 0.0%. After taking an image, ΔH, ΔV, ΔS, ΔY, ΔCr, ΔCb values calculated. It is believed that polyamide produced study can be used for high-functional protective clothing, sensors by applying stealth functions.

Язык: Английский

Процитировано

0