Recent progress, challenges, and future perspectives of electrochemical biosensing of aflatoxins DOI

S Doddanagowada,

Venkata Narayana Palakollu, S.V. Prabhakar Vattikuti

et al.

Microchimica Acta, Journal Year: 2024, Volume and Issue: 192(1)

Published: Dec. 18, 2024

Language: Английский

Ternary Metal (W–Ni–Sr) Oxide@Polypyrrole Nanotubes: A New Frontier in the Electrochemical Detection of Promethazine Hydrochloride (PMHC) DOI
Shobha Purushothama,

Sirisha Subbareddy,

Santhosh Arehalli Shivamurthy

et al.

Langmuir, Journal Year: 2025, Volume and Issue: unknown

Published: Jan. 8, 2025

Promethazine hydrochloride (PMHC) is a vital drug that used as an anticholinergic, antipsychotic, antihistaminic, analgesic, sedative, and neuroleptic. However, the overdosage of PMHC also causes reproductive variations, cardiac changes, hypotension, endocrinal variations. Hence, detection crucial. Therefore, in this work electrochemical method for reported. The fabrication modified electrode built with tungsten (W), nickel (N), strontium (S) ternary oxide (tWNSO). To best our knowledge, tWNSO preparation reported first time literature. prepared deposited on polypyrrole nanotubes, nanocomposite formed confirmed by various physical characterizations like XRD, SEM, TEM, UV–vis spectroscopy, FTIR DFT studies PMHC. Thus, obtained working fabricated tWNSO/PPyNTs/GCE has effective surface area 0.0436 cm2. Also, no fouling was observed. limit analyte 3.66 nM, quantification 11.10 sensitivity identifying found to be 20.10 μA μM–1 cm–2. effectively detects while demonstrating excellent stability reproducibility.

Language: Английский

Citations

1

Highly Specific Non-Enzymatic Electrochemical Sensor for the Detection of Uric Acid Using Carboxylated Multiwalled Carbon Nanotubes Intertwined with GdS-Gd2O3 Nanoplates in Human Urine and Serum DOI
Srishti Verma,

Atreyee Sen,

Nirmita Dutta

et al.

Langmuir, Journal Year: 2024, Volume and Issue: unknown

Published: Oct. 2, 2024

Herein, the electrochemical sensing efficacy of carboxylic acid functionalized multiwalled carbon nanotubes (C-MWCNT) intertwined with coexisting phases gadolinium monosulfide (GdS) and oxide (Gd

Language: Английский

Citations

4

Optimizing surface states to elevate xylene gas sensing characteristics in ZnCo2O4 microspheres DOI

Chenlu Hu,

Rui Jiang,

Yanxu Feng

et al.

Sensors and Actuators B Chemical, Journal Year: 2025, Volume and Issue: 430, P. 137369 - 137369

Published: Feb. 1, 2025

Language: Английский

Citations

0

An electrochemical immunosensor based on an antibody-ferrocene-functionalized covalent organic framework DOI
Qiang Fang, Yingbo Lu, Jianying Huang

et al.

Chinese Chemical Letters, Journal Year: 2025, Volume and Issue: unknown, P. 111218 - 111218

Published: April 1, 2025

Language: Английский

Citations

0

Titanium dioxide nanoparticles-decorated reduced graphene oxide for highly sensitive electrochemical detection of chloramphenicol DOI

S. Anitha Devi,

Gutturu Rajasekhara Reddy,

M. S. Narasinga Rao

et al.

Microchemical Journal, Journal Year: 2025, Volume and Issue: unknown, P. 113717 - 113717

Published: April 1, 2025

Language: Английский

Citations

0

A Dual Nano-Signal Probe-Based Electrochemical Immunosensor for the Simultaneous Detection of Two Biomarkers in Gastric Cancer DOI Creative Commons

Li-Ting Su,

Zhenqing Yang, Hua‐Ping Peng

et al.

Biosensors, Journal Year: 2025, Volume and Issue: 15(2), P. 80 - 80

Published: Jan. 31, 2025

Detecting multiple tumor markers is of great importance. It helps in early cancer detection, accurate diagnosis, and monitoring treatment. In this work, gold nanoparticles–toluidine blue–graphene oxide (AuNPs-TB–GO) nanoparticles–carboxyl ferrocene–tungsten disulfide (AuNPs–FMC–WS2) nanocomposites were prepared for labeling Carcinoembryonic antigen (CEA) antibody Carbohydrate 72–4 (CA72-4) antibody, respectively, used as two kinds probes with different electrochemical signals. With the excellent magnetic performance biotin immune beads (IMBs), biofunctional IMBs firmly deposited on glassy carbon electrode (MGCE) surface by applying a constant field, then CEA CA72-4 immobilized avidin–biotin conjugation. The assay was based change detection peak current. Under optimum experimental conditions, linear range two-component immunosensor from 0.01 to 120 ng/mL, low limit 0.003 0.05 35 U/mL, 0.016 U/mL. results showed that proposed enabled simultaneous exhibited good reproducibility, high selectivity, sensitivity. particular, multiplexed immunoassay approach does not require sophisticated fabrication well-suited high-throughput biosensing application other areas.

Language: Английский

Citations

0

Utilization of TEP miRNAs in tumor proliferation, diagnostic evaluation, therapeutic intervention, and prognostic assessment DOI
Yuhan Wang, Ling Jiang, Jie Wang

et al.

Molecular Biology Reports, Journal Year: 2025, Volume and Issue: 52(1)

Published: March 26, 2025

Language: Английский

Citations

0

Recent progress, challenges, and future perspectives of electrochemical biosensing of aflatoxins DOI

S Doddanagowada,

Venkata Narayana Palakollu, S.V. Prabhakar Vattikuti

et al.

Microchimica Acta, Journal Year: 2024, Volume and Issue: 192(1)

Published: Dec. 18, 2024

Language: Английский

Citations

1