Graphene/PEDOT:PSS conformally wrapped encapsulated silver nanowire films for transparent electrothermal heater DOI

Yongqing Zhang,

Jiahang Zhou,

Lingui Hu

et al.

Materials Science and Engineering B, Journal Year: 2025, Volume and Issue: 318, P. 118287 - 118287

Published: April 8, 2025

Language: Английский

Fabrication of Highly Efficient Nanogold Membrane Catalysts Utilizing Ultrathin Gold Nanowires in the Presence of Thiourea DOI

Yulu Ye,

Jiahang Zhou,

Minqiang Xia

et al.

The Journal of Physical Chemistry C, Journal Year: 2025, Volume and Issue: unknown

Published: Feb. 14, 2025

Language: Английский

Citations

3

Understanding of adsorption of gold nanowire-based conductive ink on cellulosic substrate DOI

Hui He,

Lujia Xuan,

Zhengyuan Ma

et al.

Materials Letters, Journal Year: 2025, Volume and Issue: unknown, P. 138370 - 138370

Published: March 1, 2025

Language: Английский

Citations

0

Stretchable and flexible PEDOT:PSS/SWCNTs/PEO film with strain‐insensitive electrical resistance DOI Creative Commons
Zhenbang Zhang,

Fahu Yang,

Guangming Li

et al.

Polymer Composites, Journal Year: 2025, Volume and Issue: unknown

Published: March 11, 2025

Abstract The poly‐(3,4‐ethylenedioxythiophene):poly(styrenesulfonic acid) (PEDOT:PSS), single‐walled carbon nanotubes (SWCNTs), and polyethylene glycol (PEO) were composited subsequently spin‐coated on a Polydimethylsiloxane (PDMS) substrate to prepare stretchable flexible bilayer film, the electrical resistance of film was adjusted be unchanged by pre‐stretching processing. interpenetrating structure formed within PEDOT:PSS/SWCNTs/PEO when PEO concentration 5 wt%. PEDOT:PSS SWCNTs served as electric phase forming conductive path, while acted elastic phase, thereby enabling exhibit stretchability, flexibility, high conductivity. processing, which consisted sequential uniaxial stretching relaxation, resulted in wrinkling due strain exceeding deformation limit. transmittance changes films subjected processing also proved that wrinkles formed. comprising wt% 10 SWCNTs, exhibited minimum sheet 43 Ω/sq. without demonstrated stable with 50% strain. had achieved comparable level performance contemporary medical electrodes for electrocardiogram detection. Meanwhile, could utilized sensor monitoring body motion. Highlights Stretchable prepared. constructed using scanning electron microscopy Fourier transfer infrared spectra. Pre‐stretching produce wrinkled surface film. makes stability.

Language: Английский

Citations

0

Graphene/PEDOT:PSS conformally wrapped encapsulated silver nanowire films for transparent electrothermal heater DOI

Yongqing Zhang,

Jiahang Zhou,

Lingui Hu

et al.

Materials Science and Engineering B, Journal Year: 2025, Volume and Issue: 318, P. 118287 - 118287

Published: April 8, 2025

Language: Английский

Citations

0