Microchimica Acta, Journal Year: 2024, Volume and Issue: 191(11)
Published: Oct. 22, 2024
Language: Английский
Microchimica Acta, Journal Year: 2024, Volume and Issue: 191(11)
Published: Oct. 22, 2024
Language: Английский
Chemical Engineering Journal, Journal Year: 2025, Volume and Issue: unknown, P. 159639 - 159639
Published: Jan. 1, 2025
Language: Английский
Citations
2Journal of Alloys and Compounds, Journal Year: 2024, Volume and Issue: unknown, P. 177715 - 177715
Published: Nov. 1, 2024
Language: Английский
Citations
5Advanced Powder Technology, Journal Year: 2025, Volume and Issue: 36(3), P. 104789 - 104789
Published: Feb. 1, 2025
Language: Английский
Citations
0Sensors and Actuators A Physical, Journal Year: 2025, Volume and Issue: unknown, P. 116330 - 116330
Published: Feb. 1, 2025
Language: Английский
Citations
0Ceramics International, Journal Year: 2025, Volume and Issue: unknown
Published: Feb. 1, 2025
Language: Английский
Citations
0ACS Sensors, Journal Year: 2025, Volume and Issue: unknown
Published: March 25, 2025
To achieve the early diagnosis of chronic kidney disease (CKD), noninvasive hemodialysis monitoring, and accurate determination dialysis duration adequacy, a noninvasive, point-of-care, user-friendly device should be developed. Here, flexible, room temperature NH3 gas sensor sensitive to key breath biomarkers CKD─NH3 creatinine─was fabricated. The had detection limits 100 ppb for 1 ppm creatinine. Clinically, total 96 exhaled samples, half from 39 CKD patients other 48 healthy controls were collected analyzed. With assistance pattern recognition algorithm , was achieved by sensor, with PCA being used due sensor's cross-sensitivity biomarkers. Diagnostic models distinguishing versus non-CKD early-stage advanced-stage constructed using SVM algorithm, achieving an overall accuracy 0.93 0.94, area under curve (AUC) values 0.97 0.99 all subjects in receiver operating characteristic (ROC) analysis, respectively. processes monitored real-time, response exhibiting ideal exponential decay over time. showed strong positive correlation serum creatinine levels (r = 0.85) moderate blood urea nitrogen 0.62), both which are clinical diagnostic indicators CKD. These good results, as 54% samples patients. results suggest that could serve alternative traditional tests renal function evaluation diagnosis. Overall, this demonstrates great potential practice CKD, monitoring daily health status patients, optimizing schedule, process real-time.
Language: Английский
Citations
0Materials & Design, Journal Year: 2024, Volume and Issue: 246, P. 113367 - 113367
Published: Oct. 1, 2024
Language: Английский
Citations
2Ceramics International, Journal Year: 2024, Volume and Issue: unknown
Published: Dec. 1, 2024
Language: Английский
Citations
2International Journal of Electrochemical Science, Journal Year: 2024, Volume and Issue: unknown, P. 100797 - 100797
Published: Sept. 1, 2024
Language: Английский
Citations
1Microchimica Acta, Journal Year: 2024, Volume and Issue: 191(11)
Published: Oct. 22, 2024
Language: Английский
Citations
1