Elsevier eBooks, Journal Year: 2024, Volume and Issue: unknown, P. 13 - 53
Published: Jan. 1, 2024
Language: Английский
Elsevier eBooks, Journal Year: 2024, Volume and Issue: unknown, P. 13 - 53
Published: Jan. 1, 2024
Language: Английский
Coordination Chemistry Reviews, Journal Year: 2023, Volume and Issue: 500, P. 215542 - 215542
Published: Nov. 15, 2023
Language: Английский
Citations
67Ceramics International, Journal Year: 2024, Volume and Issue: 50(9), P. 14238 - 14246
Published: Jan. 25, 2024
Language: Английский
Citations
13Surfaces and Interfaces, Journal Year: 2024, Volume and Issue: 51, P. 104666 - 104666
Published: June 24, 2024
Language: Английский
Citations
7The Science of The Total Environment, Journal Year: 2024, Volume and Issue: 928, P. 172048 - 172048
Published: April 4, 2024
Language: Английский
Citations
6Sensors and Actuators B Chemical, Journal Year: 2024, Volume and Issue: 421, P. 136442 - 136442
Published: Aug. 14, 2024
Language: Английский
Citations
6Ceramics International, Journal Year: 2024, Volume and Issue: 50(8), P. 13113 - 13124
Published: Jan. 21, 2024
Language: Английский
Citations
5ACS Applied Nano Materials, Journal Year: 2024, Volume and Issue: 7(8), P. 9635 - 9648
Published: April 9, 2024
In the present study, an electrochemical sensor based on a Cr-doped WO3 nanostructure was designed and exploited for pharmaceutical drug analysis. nanostructures were prepared by treating W Cr precursors with hydrothermal condensation. A thorough characterization conducted structural elemental insights using scanning electron microscopy, X-ray powder diffraction, transmission photoelectron spectroscopy methods. The optimized response obtained 1.68 atom % of in lattice. developed nanoparticles employed detection antiandrogen drugs such as flutamide (FLTM) nilutamide (NLTM) cyclic voltammetry square wave techniques. to evaluate physiochemical thermodynamical parameters voltammetric process investigating effect scan rates temperatures quasi-reversible signals FLTM NLTM. Cr-WO3/CPE shows sensitivity 24.9 49.1 μA μM–1cm–2 NLTM limits 4.2 3.07 nM, respectively. detect desired moiety urine samples (real synthetic) drugs; good recovery values demonstrating applicability selectivity supported excipient interference investigation. Thus, methods hold potential future research identifying additional bioactive molecules clinical trials.
Language: Английский
Citations
5Journal of Hazardous Materials, Journal Year: 2024, Volume and Issue: unknown, P. 136289 - 136289
Published: Oct. 1, 2024
Language: Английский
Citations
5ACS Omega, Journal Year: 2025, Volume and Issue: unknown
Published: Feb. 21, 2025
Developing sensitive sensors to trimethylamine (TMA) remains a topic of great interest in areas such as food quality analysis and disease biomarkers. To address this issue, chemiresistive were proposed using graphene quantum dots (GQDs) with different proportions hydroxyl (GQDs-OH), epoxy (GQDs-epoxy), carboxyl (GQDs-COOH) groups. These materials exhibited sensitivities TMA, GQDs-OH being the most sensitive, presenting detection limit 0.3 ppm response about 4 2.5 times higher than those GQDs-COOH GQDs-Epoxy, respectively. This difference sensitivity was elucidated by building, based on density functional theory calculations, potential energy curves interaction between TMA three GQD models. Noncovalent atoms molecular also used explain each model. Our results highlight that proportion oxygen groups has major role modulating against group providing greater sensitivity. through computational simulations, which explained lower other materials. work serves practical guide, demonstrating importance coupling experimental methods achieve deeper understanding sensing results.
Language: Английский
Citations
0Nanoscale, Journal Year: 2025, Volume and Issue: unknown
Published: Jan. 1, 2025
Schematic representation of MXene based gas sensors: including synthesis, materials design, application and challenges.
Language: Английский
Citations
0