Modified Biochar Adsorption Combined with Alkaline Solution Absorption for Sulfur-Containing Odor Gases Removal from Domestic Waste Transfer Stations DOI Creative Commons
Wei Wei, Ningjie Wang, Xiaolei Zhang

et al.

Separations, Journal Year: 2024, Volume and Issue: 11(12), P. 361 - 361

Published: Dec. 23, 2024

Odor emission has become a major issue in waste transfer stations. Hydrogen sulfide, methyl mercaptan (MM), and dimethyl disulfide (DMDS) are the main odorous gases. They have low odor threshold difficult to remove. In this study, pine bark biochar was produced modified with metal ions, including Ni2+, Ti2+, Mn2+, Zn2+, Mg2+, Cu2+. It then used for removal of hydrogen mercaptan, disulfide. Among all modifications, Cu2+ showed best sorption capacity, maximum amounts were 20.50 mg/g H2S, 36.50 MM, 57.98 DMDS. To understand adsorption, BET, SEM, XPS original performed. This illustrated that modification increased surface area porosity, thus enhancing adsorption capacity. alkaline absorption it found three gases pH increase. Based on results, combined process called absorption–adsorption established treat gas generated local station. Thirty-one components detected The proceeded 30 days, these not effluent during treatment. Regarding DMDS, they even after 90 days. indicates high capacity toward addition, is simple easy operate. suggests suitable treating places where there no technician, needs efficient study provides feasible alternative domestic stations control problem.

Language: Английский

Adjusting the electronic structure of Keggin-type polyoxometalates to construct S-scheme heterojunction for photocatalytic hydrogen evolution DOI
Xinyu Miao, Hao Yang, Jie He

et al.

Acta Physico-Chimica Sinica, Journal Year: 2025, Volume and Issue: unknown, P. 100051 - 100051

Published: Jan. 1, 2025

Language: Английский

Citations

10

Oxygen vacancy-mediated BiVO4/Bi3O4Br S-scheme heterojunction for enhanced photocatalytic degradation of antibiotics DOI
Ju Zhang, Jianhao Chen, Te‐Hua Fang

et al.

Journal of Colloid and Interface Science, Journal Year: 2025, Volume and Issue: 691, P. 137458 - 137458

Published: March 30, 2025

Language: Английский

Citations

0

Fabrication of Fe-Doped UiO-66-NH2@b-TiO2 Z-Scheme Heterojunction for Enhanced Visible Light-Driven Degradation of VSCs and Antibiotics DOI
Tian Li,

Xingkai Lu,

Yuyao Xu

et al.

Environmental Research, Journal Year: 2025, Volume and Issue: unknown, P. 121498 - 121498

Published: March 1, 2025

Language: Английский

Citations

0

Construction of superhydrophilic/superhydrophobic composite photocatalysts for efficient gas–liquid-solid photocatalytic degradation of methyl mercaptan DOI

Zichang Yang,

Yuyao Xu, Li He

et al.

Chemical Engineering Journal, Journal Year: 2025, Volume and Issue: unknown, P. 162913 - 162913

Published: April 1, 2025

Language: Английский

Citations

0

Schottky junctions integrated with S-scheme heterojunctions in recyclable loaded ZnIn2S4/UiO-66/calcined graphite felt photocatalysts with enhanced carrier separation for photocatalytic degradation DOI

Jiajun An,

J.L. Wang,

Yanan Li

et al.

Separation and Purification Technology, Journal Year: 2024, Volume and Issue: unknown, P. 130814 - 130814

Published: Nov. 1, 2024

Language: Английский

Citations

3

Full solar-spectrum available Z-scheme MOF-on-MOF heterostructure for highly efficient photocatalytic VSCs removal DOI
Yuyao Xu, He Li,

Zichang Yang

et al.

Separation and Purification Technology, Journal Year: 2024, Volume and Issue: 354, P. 128942 - 128942

Published: July 24, 2024

Language: Английский

Citations

1

Modified Biochar Adsorption Combined with Alkaline Solution Absorption for Sulfur-Containing Odor Gases Removal from Domestic Waste Transfer Stations DOI Creative Commons
Wei Wei, Ningjie Wang, Xiaolei Zhang

et al.

Separations, Journal Year: 2024, Volume and Issue: 11(12), P. 361 - 361

Published: Dec. 23, 2024

Odor emission has become a major issue in waste transfer stations. Hydrogen sulfide, methyl mercaptan (MM), and dimethyl disulfide (DMDS) are the main odorous gases. They have low odor threshold difficult to remove. In this study, pine bark biochar was produced modified with metal ions, including Ni2+, Ti2+, Mn2+, Zn2+, Mg2+, Cu2+. It then used for removal of hydrogen mercaptan, disulfide. Among all modifications, Cu2+ showed best sorption capacity, maximum amounts were 20.50 mg/g H2S, 36.50 MM, 57.98 DMDS. To understand adsorption, BET, SEM, XPS original performed. This illustrated that modification increased surface area porosity, thus enhancing adsorption capacity. alkaline absorption it found three gases pH increase. Based on results, combined process called absorption–adsorption established treat gas generated local station. Thirty-one components detected The proceeded 30 days, these not effluent during treatment. Regarding DMDS, they even after 90 days. indicates high capacity toward addition, is simple easy operate. suggests suitable treating places where there no technician, needs efficient study provides feasible alternative domestic stations control problem.

Language: Английский

Citations

0