Electro-dewatering of activated sludge of sewage treatment plants, Ternopol DOI Creative Commons
Orest Verbovskyi, Vadym Orel, Oksana Matsiyevska

et al.

Problems of Water supply Sewerage and Hydraulic, Journal Year: 2024, Volume and Issue: 48, P. 12 - 17

Published: Dec. 12, 2024

The sewage sludge formed at wastewater treatment plants constitutes a small percentage of the volume treated wastewater. However, costs associated with and disposal account for lion's share operational expenses plants. contains harmful toxic substances. On other hand, is source carbon, nutrients, trace elements, meaning it can be effectively utilized. An important stage in its dewatering, particularly use electric current. study investigated electro-dewatering activated moisture content 98% from secondary clarifiers Ternopil plant using direct Experiments were conducted on laboratory setup U-shaped glass tube carbon rod anode cathode. effect field was observed during fading period, when, after significant amount water had been separated sludge, process slowed down. obtained results compared those graphite flat cathode, as reported by researchers. Electro-dewatering both setups produced practically same effect. It confirmed that dewatering current applied drying beds

Language: Английский

Structural Characterization of Modified Straw Combined with CPAM Conditioned Sludge Filter Cake and Analysis of Its Structure-Performance Relationship with Sludge Dewatering Performance DOI
Qiyong Yang, Yanbin Zhao, Qingfang Zhang

et al.

Journal of environmental chemical engineering, Journal Year: 2024, Volume and Issue: unknown, P. 115266 - 115266

Published: Dec. 1, 2024

Language: Английский

Citations

1

Mechanistic insights into melanoidins-induced hydrophilicity of thermal hydrolyzed sludge and its impact on dewaterability DOI
Qian Zhang,

Junyue Xu,

Jiamian Wang

et al.

Bioresource Technology, Journal Year: 2024, Volume and Issue: 416, P. 131766 - 131766

Published: Nov. 7, 2024

Language: Английский

Citations

0

Electro-dewatering of activated sludge of sewage treatment plants, Ternopol DOI Creative Commons
Orest Verbovskyi, Vadym Orel, Oksana Matsiyevska

et al.

Problems of Water supply Sewerage and Hydraulic, Journal Year: 2024, Volume and Issue: 48, P. 12 - 17

Published: Dec. 12, 2024

The sewage sludge formed at wastewater treatment plants constitutes a small percentage of the volume treated wastewater. However, costs associated with and disposal account for lion's share operational expenses plants. contains harmful toxic substances. On other hand, is source carbon, nutrients, trace elements, meaning it can be effectively utilized. An important stage in its dewatering, particularly use electric current. study investigated electro-dewatering activated moisture content 98% from secondary clarifiers Ternopil plant using direct Experiments were conducted on laboratory setup U-shaped glass tube carbon rod anode cathode. effect field was observed during fading period, when, after significant amount water had been separated sludge, process slowed down. obtained results compared those graphite flat cathode, as reported by researchers. Electro-dewatering both setups produced practically same effect. It confirmed that dewatering current applied drying beds

Language: Английский

Citations

0