A Dual-Functional and Efficient MOF-5@MWCNTs Electrochemical Sensing Device for the Measurement of Trace-Level Acetaminophenol and Dopamine DOI Creative Commons
Jianxia Gu,

Shuting Lang,

Zhanbin Jin

et al.

Molecules, Journal Year: 2024, Volume and Issue: 29(23), P. 5534 - 5534

Published: Nov. 23, 2024

The design and construction of dual-functional high-efficiency electrochemical sensors are necessary for quantitative detection. In this work, a zinc-based metal-organic framework (MOF-5) multi-walled carbon nanotubes (MWCNTs) were combined in situ through simple solvothermal reaction to obtain an MOF-5@MWCNTs composite. composite exhibits large surface area, hierarchical pore structure, excellent conductivity, enhanced performance the detection acetaminophenol (AP) dopamine (DA). Remarkably, synergistic effects between MOF-5 MWCNTs enable sensor based on quantitatively determine AP DA at trace levels. Under optimal conditions, proposed features relatively wide linear ranges 0.005-600 μM 0.1-60 DA, respectively, with very low limits (LODs) 0.061 0.0075 DA. Importantly, demonstrates reproducibility, stability, anti-interference ability, making it suitable practical applications urine tap water samples acceptable recoveries. successful integration results robust versatile sensing platform rapid reliable

Language: Английский

Prepared Hollow Nanosphere MoO2/rGO Composite for low concentration Dopamine Detection DOI
Lihong Liu, Bo Li, Ming Yang

et al.

Electrochimica Acta, Journal Year: 2025, Volume and Issue: unknown, P. 145717 - 145717

Published: Jan. 1, 2025

Language: Английский

Citations

1

Wear Performance of MoS2 Doped Al2O3 CPED Coatings on TC6 Titanium Alloy DOI
Shaoqing Wang,

Xiangqing Wu,

Faqin Xie

et al.

Materials Chemistry and Physics, Journal Year: 2024, Volume and Issue: 325, P. 129734 - 129734

Published: July 16, 2024

Language: Английский

Citations

3

Bovine Serum Albumin Template-Mediated Fabrication of Ruthenium Dioxide/Multiwalled Carbon Nanotubes: High-Performance Electrochemical Dopamine Biosensing in Human Serum DOI
Peng Lei, Shan Zhao, Muhammad Asif

et al.

Langmuir, Journal Year: 2024, Volume and Issue: 40(22), P. 11635 - 11641

Published: May 22, 2024

The presence of abnormal dopamine (DA) levels may cause serious neurological disorders, therefore, the quantitative analysis DA and its related research are great significance for ensuring health. Herein, bovine serum albumin (BSA) template method has been proposed preparation catalytically high-performance ruthenium dioxide/multiwalled carbon nanotube (RuO

Language: Английский

Citations

0

Preparation and application of boron and fluorine co-doped rGO electrochemical sensor DOI
Yan Jiang, Guosheng Wang

Journal of the Indian Chemical Society, Journal Year: 2024, Volume and Issue: 101(10), P. 101310 - 101310

Published: Aug. 13, 2024

Language: Английский

Citations

0

Willow catkin template synthesis of NiS@NSC hollow tubes for highly sensitive dual-function electrochemical detection of acetaminophen and Cu2+ DOI
Menghao Li, Yu-Ying Xin,

X. H. Sun

et al.

Microchimica Acta, Journal Year: 2024, Volume and Issue: 191(11)

Published: Oct. 23, 2024

Language: Английский

Citations

0

A Dual-Functional and Efficient MOF-5@MWCNTs Electrochemical Sensing Device for the Measurement of Trace-Level Acetaminophenol and Dopamine DOI Creative Commons
Jianxia Gu,

Shuting Lang,

Zhanbin Jin

et al.

Molecules, Journal Year: 2024, Volume and Issue: 29(23), P. 5534 - 5534

Published: Nov. 23, 2024

The design and construction of dual-functional high-efficiency electrochemical sensors are necessary for quantitative detection. In this work, a zinc-based metal-organic framework (MOF-5) multi-walled carbon nanotubes (MWCNTs) were combined in situ through simple solvothermal reaction to obtain an MOF-5@MWCNTs composite. composite exhibits large surface area, hierarchical pore structure, excellent conductivity, enhanced performance the detection acetaminophenol (AP) dopamine (DA). Remarkably, synergistic effects between MOF-5 MWCNTs enable sensor based on quantitatively determine AP DA at trace levels. Under optimal conditions, proposed features relatively wide linear ranges 0.005-600 μM 0.1-60 DA, respectively, with very low limits (LODs) 0.061 0.0075 DA. Importantly, demonstrates reproducibility, stability, anti-interference ability, making it suitable practical applications urine tap water samples acceptable recoveries. successful integration results robust versatile sensing platform rapid reliable

Language: Английский

Citations

0