A simple technique for the determination of molybdenum (Ⅵ) based on dispersive surfactant micelle-mediated extraction and image colorimetric analysis DOI
Leila Khoshmaram,

Fatemeh Hassani-Zadeh

International Journal of Environmental & Analytical Chemistry, Journal Year: 2024, Volume and Issue: unknown, P. 1 - 14

Published: Dec. 15, 2024

In this study, the potential of dispersive surfactant micelle-mediated extraction combined with image colorimetric analysis was assessed for extraction, preconcentration, and determination molybdenum (VI) in environmental samples. approach, cationic cetyltrimethylammonium bromide (CTAB) utilised as a complexing agent, ethanol chosen solvent self-assembly agent. Initially, mixture CTAB is injected into test tube, resulting formation cloudy solution due to dispersion particles aqueous phase. step, coloured ternary complexes obtained from reaction Mo(VI) ions pyrogallol red (PR) presence iodide are extracted by through process. After centrifuging, surfactant-rich phase dissolved 1 mL dimethylformamide (DMF) analysed using smartphone-based self-constructed colorimeter commercial UV-Vis spectrophotometer. mentioned colorimeter, digital final performed based on RGB (Red, Green, Blue) colour model, value R channel used acquire analytical signal. Under optimal conditions, linear range 5–100 μg L−1 limit detection (LOD) 2.1 were achieved colorimeter. Additionally, 15–250 L−1, LOD 3.3 spectrophotometric analysis. Ultimately, proposed method successfully determine various samples, satisfactory recoveries ranging 96 109%.

Language: Английский

Determination of Victoria blue in water samples using ultrasound-assisted liquid-phase microextraction based on deep eutectic solvent: A comparison study of spectrophotometric and smartphone imaging techniques DOI Creative Commons

Zahra Khalifeh,

Hamid Reza Rajabi,

Ali Gorjizadeh Kohvade

et al.

Results in Chemistry, Journal Year: 2025, Volume and Issue: unknown, P. 102054 - 102054

Published: Jan. 1, 2025

Language: Английский

Citations

0

Octylamine-oxalic acid (Oct-Oxa) deep eutectic solvent for the separation of Sudan II from food samples DOI
Mustafa Soylak,

Hassan Elzain Hassan Ahmed,

M Konneh

et al.

Food Chemistry, Journal Year: 2024, Volume and Issue: 464, P. 141658 - 141658

Published: Oct. 15, 2024

Language: Английский

Citations

3

Detection of ammonia in aquaculture wastewater using mango leaf extract-immobilized paper sensors and smartphone colorimetric analysis DOI
Farhad Nadi, Shahadat Hossain, Romi Fadillah Rahmat

et al.

Microchemical Journal, Journal Year: 2024, Volume and Issue: 207, P. 112257 - 112257

Published: Nov. 26, 2024

Language: Английский

Citations

2

An Efficient and Colorimetric Method for Lipase-Catalyzed Glycerolysis Activity Assay DOI
Jiale Liu, Wan Wei,

Shupeng Yu

et al.

Published: Jan. 1, 2024

Language: Английский

Citations

0

A simple technique for the determination of molybdenum (Ⅵ) based on dispersive surfactant micelle-mediated extraction and image colorimetric analysis DOI
Leila Khoshmaram,

Fatemeh Hassani-Zadeh

International Journal of Environmental & Analytical Chemistry, Journal Year: 2024, Volume and Issue: unknown, P. 1 - 14

Published: Dec. 15, 2024

In this study, the potential of dispersive surfactant micelle-mediated extraction combined with image colorimetric analysis was assessed for extraction, preconcentration, and determination molybdenum (VI) in environmental samples. approach, cationic cetyltrimethylammonium bromide (CTAB) utilised as a complexing agent, ethanol chosen solvent self-assembly agent. Initially, mixture CTAB is injected into test tube, resulting formation cloudy solution due to dispersion particles aqueous phase. step, coloured ternary complexes obtained from reaction Mo(VI) ions pyrogallol red (PR) presence iodide are extracted by through process. After centrifuging, surfactant-rich phase dissolved 1 mL dimethylformamide (DMF) analysed using smartphone-based self-constructed colorimeter commercial UV-Vis spectrophotometer. mentioned colorimeter, digital final performed based on RGB (Red, Green, Blue) colour model, value R channel used acquire analytical signal. Under optimal conditions, linear range 5–100 μg L−1 limit detection (LOD) 2.1 were achieved colorimeter. Additionally, 15–250 L−1, LOD 3.3 spectrophotometric analysis. Ultimately, proposed method successfully determine various samples, satisfactory recoveries ranging 96 109%.

Language: Английский

Citations

0