A multifunctional fluorescence sensor based Zn(II) metal-organic framework for rapid and sensitive detection Fe3+ and Al3+
Xiaojing Mao,
No information about this author
Huachang Li,
No information about this author
Yehong Shi
No information about this author
et al.
Polyhedron,
Journal Year:
2024,
Volume and Issue:
unknown, P. 117246 - 117246
Published: Oct. 1, 2024
Language: Английский
Two three-dimensional coordination polymers as fluorescence probes for the detection of nitrobenzene, tetracycline, fluazinam and their application in green pepper
Lulu Dong,
No information about this author
Hua Yang,
No information about this author
Xuehua Sun
No information about this author
et al.
Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy,
Journal Year:
2024,
Volume and Issue:
324, P. 124934 - 124934
Published: Aug. 12, 2024
Language: Английский
Eu-MOF-based highly sensitive and selective luminescence probe for trace, in situ and visual detection of flunitrazepam
Siyu Chen,
No information about this author
Yunliang Qiu,
No information about this author
Shuaibing Yu
No information about this author
et al.
Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy,
Journal Year:
2024,
Volume and Issue:
326, P. 125226 - 125226
Published: Sept. 28, 2024
Language: Английский
A Novel Multifunctional Eu (III)‐MOF Luminescence Sensor for Detecting NB, Fe3+, and Cr2O72− With Outstanding Sensitivities and Selectivities
Jiahui Li,
No information about this author
S F Zhang,
No information about this author
Liming Fan
No information about this author
et al.
Applied Organometallic Chemistry,
Journal Year:
2024,
Volume and Issue:
unknown
Published: Nov. 13, 2024
ABSTRACT
The
bowl‐shaped
flexible
carboxylic
acid
zwitterion
1,1′,1″‐(2,4,6‐trimethylbenzene‐1,3,5‐triyl)tris
(methylene)‐tris(4‐carboxy‐pyridinium)tribromide
(H
3
L
Br
)
ligand‐based
lanthanide
metal–organic
framework
(Ln‐MOF)
was
synthesized
for
the
first
time
under
solvothermal
conditions.
Single
crystal
X‐ray
diffraction
analysis
indicates
that
molecular
formula
of
Ln‐MOF
is
[Eu
2
O)
4
]·2H
O
(
1
).
Luminescence
sensing
experiments
demonstrate
shows
obvious
fluorescence
quenching
nitrobenzene
(NB),
Fe
3+
,
and
Cr
7
2−
with
low
detection
limits
0.118
μM,
9.098
nM,
17.409
respectively.
can
be
regarded
as
a
luminescence
sensor
multiple
functions,
displaying
high
selectivity,
wonderful
antiinterference
ability,
outstanding
sensitivity,
recyclability
to
detect
NB,
.
Language: Английский
A multifunctional Er-MOF for Methylene Blue adsorption and CO2 cycloaddition catalysis
Miao Jiang,
No information about this author
Peng-Li Zhao,
No information about this author
Yong-Ning Yue
No information about this author
et al.
Journal of Molecular Structure,
Journal Year:
2024,
Volume and Issue:
1316, P. 138943 - 138943
Published: June 15, 2024
Language: Английский
A Multifunctional Fluorescence Sensor Based Zn(Ii) Metal - Organic Framework for Rapid and Sensitive Detection Fe3+ and Al3+
Xiaojing Mao,
No information about this author
huangchang li,
No information about this author
yehong shi
No information about this author
et al.
Published: Jan. 1, 2024
Recognition
and
detection
of
Fe3+
Al3+
ions
in
water
are
important
for
human
health
life.
Herein,
a
novel
multifunctional
fluorescence
sensor
based
on
zinc-based
metal-organic
frameworks
(Zn-MOF)
was
developed
using
zinc
nitrate
hexahydrate
pyridine-2,5-dicarboxylic
acid
by
solvothermal
condition,
characterized
X-ray
single
crystal
diffraction,
elemental
analysis,
powder
diffraction
(PXRD),
etc.
The
PXRD
experiment
results
observed
that
the
structure
Zn-MOF
is
rearranged
after
molecules
exchanged
all
3
DMF
solvates
pores.
Fluorescent
sensing
experiments
revealed
exhibits
high
sensitivity
detecting
significant
quenching.The
limit
(LOD)
were
0.18
μM
0.064
μM,
respectively.
anti-interference
revealing
has
selectivity
to
detect
Al3+.
In
addition,
quenching
mechanism
demonstrated
be
attributed
inner
filter
effect
(IFE).
Furthermore,
real
sample
tap
water,
recoveries
103.0%
-
107.9%
106.1%
110.5%,
respectively,
relative
standard
deviations
(RSD)
less
than
7.42%
6.20%,
This
work
provided
an
reliable
method
quantitative
successfully
applied
with
satisfactory
recovery
precision.
Language: Английский