NiFeCo-modified bucky paper electrodes for sensitive and selective uric acid detection DOI
Anju Joshi,

Gymama Slaughter

Microchemical Journal, Journal Year: 2024, Volume and Issue: unknown, P. 112348 - 112348

Published: Dec. 1, 2024

Language: Английский

Carbon-Based Smart Sensors for Environmental Pollution Detection DOI

Shoaib Mukhtar,

Abid Ali,

Sameer Aryan

et al.

Published: Jan. 1, 2025

Language: Английский

Citations

0

Electrochemical carbon-based sensors for non-enzymatic uric acid sensing DOI
Anju Joshi,

Gymama Slaughter

Microchemical Journal, Journal Year: 2024, Volume and Issue: unknown, P. 112331 - 112331

Published: Nov. 1, 2024

Language: Английский

Citations

2

Cobalt‐Based Ferrite Modified Carbon Nanotubes Fibers for Flexible and Disposable Microelectrode Toward Electrochemical Glucose Sensing DOI Open Access
Abid Ali, Rizwan Shoukat, Ahmad Raza Ashraf

et al.

Analytical Science Advances, Journal Year: 2024, Volume and Issue: 5(11-12)

Published: Oct. 13, 2024

Glucose detection is critical in clinical health and the food industry, particularly diagnosis of blood sugar levels. Carbon-based fiber materials have recently featured prominently as non-enzymatic electrochemical glucose detectors. Herein, cobalt-based ferrite (CoFe

Language: Английский

Citations

0

Cobalt Ferrite-Modified Nickel Foam as Electrochemical Uric Acid Sensor Towards Biological and Food Sensing Applications DOI
Josfel Flora John, D. Durgalakshmi, Shanthi Subashchandran

et al.

Journal of The Electrochemical Society, Journal Year: 2024, Volume and Issue: 171(11), P. 117502 - 117502

Published: Jan. 11, 2024

Ferrites are effectively used in electrochemical uric acid (UA) sensing applications. Herein, we synthesised cobalt ferrite (CoFe 2 O 4 ) nanoparticles by one step solution combustion method. The prepared CoFe was coated on nickel foam (NF) substrate to fabricate the electrode and tested using phosphate buffer saline (PBS). small crystallite size of 14 nm as well large area active sites 0.139 cm contributed towards enhanced sensitivity 0.735 mA.mM −1 −2 . limit detection (LOD) @NF sensor is 26.24 μM. UA occurs an adsorption-controlled kinetics electrostatic interaction at a pH ∼7.2 where anion negatively charge while surface positively charged it displays quasi-reversible reaction. Additionally, repeatability, selectivity, reproducibility were investigated. real-time application validated spot-urine, commercial milk Barracuda fish samples, which show recovery percentage between 99.5% 101.8%. shelf-life observed be 28 days. Hence, this highly sensitive can for clinical diagnosis hyperuricemia food safety purposes.

Language: Английский

Citations

0

NiFeCo-modified bucky paper electrodes for sensitive and selective uric acid detection DOI
Anju Joshi,

Gymama Slaughter

Microchemical Journal, Journal Year: 2024, Volume and Issue: unknown, P. 112348 - 112348

Published: Dec. 1, 2024

Language: Английский

Citations

0