Cerebellar Pathology in Forensic and Clinical Neuroscience
Ageing Research Reviews,
Journal Year:
2025,
Volume and Issue:
unknown, P. 102697 - 102697
Published: Feb. 1, 2025
Language: Английский
In vivorat-brain mapping of multiple gray matter water populations using nonparametric D(ω)-R1-R2 distributions MRI
bioRxiv (Cold Spring Harbor Laboratory),
Journal Year:
2024,
Volume and Issue:
unknown
Published: June 9, 2024
Abstract
Massively
Multidimensional
Diffusion
MRI
combines
tensor-valued
encoding,
oscillating
gradients,
and
diffusion-relaxation
correlation
to
provide
multicomponent
sub-voxel
parameters
depicting
the
tissue
microstructure.
This
method
was
successfully
implemented
ex
vivo
in
micro-imaging
systems
clinical
conditions
but
with
a
reduced
diffusion
frequency
(
ω
)
range
due
use
of
classical
encoding.
We
demonstrate
here
its
preclinical
implementation
protocol
389
contrast
images
probing
wide
18
92
Hz
at
b
-values
up
2.1
ms/µm
2
enabled
by
modulated
gradient
waveforms
combined
multislice
high-resolution
low-distortion
EPI
acquisition
segmented
full
reversed
phase-encode
acquisition.
framework
allows
identification
-dependence
rat
cerebellum
olfactory
bulb
gray
matter
(GM)
parameter
distributions
are
shown
resolve
two
water
pools
GM
different
coefficients,
shapes,
-dependence,
relaxation
rates,
spatial
repartition
whose
attribution
specific
microstructure
could
modify
current
understanding
origin
restriction
GM.
Language: Английский
In vivo rat brain mapping of multiple gray matter water populations using nonparametric D(ω)‐R1‐R2 distributions MRI
NMR in Biomedicine,
Journal Year:
2024,
Volume and Issue:
unknown
Published: Nov. 24, 2024
Abstract
Massively
multidimensional
diffusion
magnetic
resonance
imaging
combines
tensor‐valued
encoding,
oscillating
gradients,
and
diffusion‐relaxation
correlation
to
provide
multicomponent
subvoxel
parameters
depicting
some
tissue
microstructural
features.
This
method
was
successfully
implemented
ex
vivo
in
microimaging
systems
clinical
conditions
with
gradient
waveform
of
variable
duration
giving
access
a
narrow
frequency
(
ω
)
range.
We
demonstrate
here
its
preclinical
implementation
protocol
389
contrast
images
probing
wide
range
18
92
Hz
at
b
‐values
up
2.1
ms/μm
2
enabled
by
the
use
modulated
waveforms
combined
multislice
high‐resolution
low‐distortion
echo
planar
acquisition
segmented
full
reversed
phase‐encode
acquisition.
framework
allows
identification
‐dependence
rat
cerebellum
olfactory
bulb
gray
matter
(GM),
parameter
distributions
are
shown
resolve
two
water
pools
GM
different
coefficients,
shapes,
‐dependence,
relaxation
rates,
spatial
repartition
whose
attribution
specific
microstructure
could
modify
current
understanding
origin
restriction
GM.
Language: Английский