Research Square (Research Square), Journal Year: 2024, Volume and Issue: unknown
Published: Sept. 13, 2024
Language: Английский
Research Square (Research Square), Journal Year: 2024, Volume and Issue: unknown
Published: Sept. 13, 2024
Language: Английский
Results in Engineering, Journal Year: 2024, Volume and Issue: 21, P. 101835 - 101835
Published: Jan. 30, 2024
Solar photovoltaic (PV) systems have become a vital renewable energy source, witnessing rapid global demand. Nevertheless, these are susceptible to faults and anomalies that can deteriorate performance yield significant consequences. Hence, this paper is dedicated reviewing recent advancements in monitoring, modeling, fault detection methods for PV systems. It encompasses diverse system types, including grid-connected, stand-alone, hybrid configurations, delves into the latest data acquisition monitoring techniques. The review also discusses various modeling approaches, empirical, analytical, numerical models, highlighting significance of model validation calibration. Furthermore, it provides comprehensive analysis model-based Overall, underscores pivotal role offers thorough comprehension available techniques enhancing management maintenance.
Language: Английский
Citations
20Results in Engineering, Journal Year: 2024, Volume and Issue: 23, P. 102359 - 102359
Published: June 13, 2024
Language: Английский
Citations
20Results in Engineering, Journal Year: 2024, Volume and Issue: 22, P. 102067 - 102067
Published: March 31, 2024
In this research, a novel initialization strategy for conventional MPPT algorithms is proposed to define the best position tracking process start over P–V curve. Consequently, global maximum power point (GMPP) becomes nearest or first among existing multiple MPPs under partial shading condition (PSC). addition, step size of applied algorithm minimized based on its proximity actual GMPP. Therefore, speed improved, and loss can be reduced by approach. The major advantages approach are eliminating need modify original algorithm, hybridizing with other algorithms, employing any complex procedures, as in metaheuristic optimization algorithms. Hence, it overcoming main drawbacks MPPT. work, simplest technique, which perturbation observation (P&O) show enhancement performance without introduce processes. MATLAB/Simulink simulation model hardware implementation digital signal processing (DSP) controller TMS320F28335 two distinct methodologies used validate outperformance when applying technique PSC various weather fluctuations. outcomes that was successful extracting peak while also improving time response, accuracy, generating oscillations.
Language: Английский
Citations
10Energy Storage and Saving, Journal Year: 2025, Volume and Issue: unknown
Published: Jan. 1, 2025
Language: Английский
Citations
1Results in Engineering, Journal Year: 2024, Volume and Issue: 23, P. 102548 - 102548
Published: July 14, 2024
Electric loads steadily increase each year due to economic and population expansion, placing electric systems close their stability limits. Also, the electrical network is a sophisticated system with various control, protection devices, power electronics. Any malfunction in these components can disrupt reliability. Therefore, ensuring safe dependable operation requires continuous precise voltage monitoring prevent instability cascading outages. Despite existence of numerous indexes, limitations often make them ineffective under varying operating conditions. In response challenges, this article proposes modern assessment index (MSAI) designed specifically assess different scenarios. The MSAI aims accurately stress levels lines, enabling operators proactively manage One key advantage its ability determine maximum allowable load loading margin, which crucial for maintaining stable changing order validate effectiveness proposed index, extensive evaluations are conducted using IEEE 30, 57, 118 bus test systems. study meticulously compares performance other prominent indicators, highlighting superiority providing predictive insights into areas prone potential contingencies. By empowering preemptive correction capabilities, reduces risk successive outages enhances overall flexibility. contingency ranking were evaluated via smooth method MATLAB environment.
Language: Английский
Citations
6Results in Engineering, Journal Year: 2024, Volume and Issue: unknown, P. 103554 - 103554
Published: Dec. 1, 2024
Language: Английский
Citations
5Results in Engineering, Journal Year: 2025, Volume and Issue: unknown, P. 103961 - 103961
Published: Jan. 1, 2025
Language: Английский
Citations
0Results in Engineering, Journal Year: 2025, Volume and Issue: unknown, P. 104400 - 104400
Published: Feb. 1, 2025
Language: Английский
Citations
0Results in Engineering, Journal Year: 2025, Volume and Issue: unknown, P. 104587 - 104587
Published: March 1, 2025
Language: Английский
Citations
0Results in Engineering, Journal Year: 2025, Volume and Issue: unknown, P. 105046 - 105046
Published: April 1, 2025
Language: Английский
Citations
0