Energy Consumption Optimization in Data Centers Using LSTM-Based Load Prediction and Dynamic Resource Allocation DOI Creative Commons

D Dang

Applied Mathematics and Nonlinear Sciences, Journal Year: 2024, Volume and Issue: 9(1)

Published: Jan. 1, 2024

Abstract With the rapid growth of data centers, optimizing energy consumption has become a critical challenge. This paper proposes an management framework that integrates Long Short-Term Memory (LSTM) networks for load prediction with dynamic resource allocation algorithm to optimize in centers. The LSTM model is employed accurately predict future workloads based on historical data, enabling proactive adjustment utilization. algorithm, informed by LSTM-based predictions, dynamically manages server operations and cooling systems through techniques such as voltage frequency scaling (DVFS) consolidation, ensuring resources are allocated efficiently real time. proposed incorporates multi-objective optimization approach balance savings system performance. We use genetic algorithms fine-tune predicted load, response Experimental results show our method achieves significant compared traditional static approaches, minimal impact service quality. research highlights potential machine learning-driven reducing environmental footprint centers while maintaining operational efficiency.

Language: Английский

Comprehensive review and future prospects on chip-scale thermal management: Core of data center’s thermal management DOI
Ziyong Li,

Hailiang Luo,

Yuguang Jiang

et al.

Applied Thermal Engineering, Journal Year: 2024, Volume and Issue: 251, P. 123612 - 123612

Published: June 6, 2024

Language: Английский

Citations

44

Rack-level cooling technologies for data centers – A comprehensive review DOI
Xiuming Li, Mengyi Li, Yingbo Zhang

et al.

Journal of Building Engineering, Journal Year: 2024, Volume and Issue: 90, P. 109535 - 109535

Published: May 5, 2024

Language: Английский

Citations

27

A Review of Non-Uniform Load Distribution and Solutions in Data Centers: Micro-Scale Liquid Cooling and Large-Scale Air Cooling DOI Creative Commons
Yifan Li,

Congzhe Zhu,

Xiuming Li

et al.

Energies, Journal Year: 2025, Volume and Issue: 18(1), P. 149 - 149

Published: Jan. 2, 2025

Nowadays, the number of transistors on electronic components is increasing exponentially leading to an ultra-high heat flux (106~107 W/m2). The non-uniform load distribution chip and local hot spots in thermal environment are key issues a data center (DC). Microchannel liquid cooling effective method inhibit accumulation chip. Optimizing air crucial approach realizing energy savings. This study summarizes latest research management by microchannel optimization DCs. existing concerning structure universality sink (MCHS), stability flow boiling new coolant, prediction spots, intelligent control system identified. Furthermore, novel strategy multi-scale synergy recommended, which expected suppress heighten temperature uniformity. review provides valuable insights into for It paves way applying innovative technologies artificial intelligence methods promote efficient operation low-carbon retrofit

Language: Английский

Citations

2

Simulation and experimental research on the optimization of airflow organization and energy saving in data centers using air deflectors DOI Creative Commons

Boyang Ma,

Haiyong Liu,

Yahui Du

et al.

Clean Energy Science and Technology, Journal Year: 2024, Volume and Issue: 2(1), P. 141 - 141

Published: March 5, 2024

The airflow organization of the data center directly affects temperature control performance and energy efficiency cooling equipment. servers at bottom rack usually suffer from insufficient rate poor effect. This is because limited distance between perforated floor, small horizontal velocity supply air flow. study aims to improve uniformity in vertical direction by deflectors, thereby further improving overall center. size installation deflectors were optimized according both experiment numerical simulation results. From results, it recommended install deflector with a width 100 mm an angle 45° under floor for single-side supply. For double-side supply, should be installed 30° achieve best distribution. Consequently, intake significantly increased, occurrence local hot spots was effectively reduced. without conducted ANSYS. results show that, increased inlet 16.98% improved dater conditioners 1.98%.

Language: Английский

Citations

7

Optimization Control Strategies and Evaluation Metrics of Cooling Systems in Data Centers: A Review DOI Open Access

Qiankun Chang,

Yuanfeng Huang,

K.P. Liu

et al.

Sustainability, Journal Year: 2024, Volume and Issue: 16(16), P. 7222 - 7222

Published: Aug. 22, 2024

In the age of digitalization and big data, cooling systems in data centers are vital for maintaining equipment efficiency environmental sustainability. Although many studies have focused on classification optimization center systems, systematic reviews using bibliometric methods relatively scarce. This review uses analysis to explore classifications, control optimizations, energy metrics aiming address research gaps. Using CiteSpace databases like Scopus, Web Science, IEEE, this study maps field’s historical development current trends. The findings indicate that, firstly, strategies, focal points. Secondly, assesses applicability air-cooled liquid-cooled different operational environments, providing practical guidance selection. Then, air demonstrates that optimizing design static pressure chamber baffles has significantly improved airflow uniformity. Finally, article advocates expanding use artificial intelligence machine learning automate collection analysis, it also calls global standardization metrics. offers new perspectives design, optimization, performance evaluation systems.

Language: Английский

Citations

5

Comprehensive review and future prospects of multi-level fan control strategies in data centers for joint optimization of thermal management systems DOI

Kunyuan Cao,

Ziyong Li,

Hailiang Luo

et al.

Journal of Building Engineering, Journal Year: 2024, Volume and Issue: 94, P. 110021 - 110021

Published: June 22, 2024

Language: Английский

Citations

4

MILP optimization of the multi-heat pump waste heat recovery system integrated with full-free cooling data center through lake water DOI
Shuyi Chen, Quan Zhang, Zhiqiang Zhai

et al.

Energy, Journal Year: 2025, Volume and Issue: unknown, P. 134823 - 134823

Published: Feb. 1, 2025

Language: Английский

Citations

0

An efficient assessment method for the thermal environment of a row-based cooling data center DOI
Ligang Wang, Yating Wang, Xuelian Bai

et al.

Applied Thermal Engineering, Journal Year: 2025, Volume and Issue: unknown, P. 126020 - 126020

Published: Feb. 1, 2025

Language: Английский

Citations

0

Optimization strategy for minimizing energy consumption of air conditioning terminal system in the Internet data center DOI
Xiaofei Huang, Junwei Yan, Xuan Zhou

et al.

Journal of Building Engineering, Journal Year: 2024, Volume and Issue: 96, P. 110315 - 110315

Published: July 30, 2024

Language: Английский

Citations

3

Research on cooling performance of a built-in cooling equipment for server rack DOI
Fei Peng,

Jinwei Zeng,

Ye Chen

et al.

Applied Thermal Engineering, Journal Year: 2025, Volume and Issue: unknown, P. 125901 - 125901

Published: Feb. 1, 2025

Language: Английский

Citations