COHERENT AMPLITUDE MODULATION IN A LASER GAS SENSOR DOI Open Access
Z. Zh. Zhanabaev

Eurasian Physical Technical Journal, Journal Year: 2023, Volume and Issue: 20(4 (46)), P. 111 - 115

Published: Dec. 19, 2023

The article is devoted to a current topic in science and technology -determining the type concentration of gas using laser. At close values green laser radiation intensity bias voltage, interference patterns time series photodiode output signal were obtained. degree coherence (more than ~0.1) made it possible distinguish between types gases their concentrations. Signal was controlled by Allan deviation values.The novelty research method choice harmonic electrical network asthe main modulation frequency. It shown that correlation functions corresponding power spectra are sensitive low-frequency fluctuations molecules clumps. This allows results methods this work be used specific cases instead large-sized expensive complexes optical instruments at room pressure temperature.

Language: Английский

Design and fabrication of an amperometric CO gas sensor and a readout circuit using a low-noise transimpedance amplifier to achieve standard analog outputs DOI
Amirhosein Asilian, S. Mohammadali Zanjani

AEU - International Journal of Electronics and Communications, Journal Year: 2023, Volume and Issue: 171, P. 154864 - 154864

Published: Aug. 22, 2023

Language: Английский

Citations

1

1/f and Random Telegraph Noise of Single-Layer Graphene Devices with Interdigitated Electrodes DOI

Georgia Samara,

Nikolaos Vasileiadis, Alexandros Mavropoulis

et al.

Published: Oct. 17, 2023

Single-layer Graphene (SLG) is a promising material for sensing applications. High performance graphene sensors can be achieved when Interdigitated Electrodes (IDE) are used. In this research work, we fabricated SLG micro-ribbon (GMR) devices with IDE having different geometric parameters. 1/f noise behavior was observed in all of the examined devices, and some cases random telegraph (RTN) signals suggesting that carrier trapping/de-trapping taking place. Our experimental results indicate geometrical characteristics have crucial impact on device performance, due to direct area dependence level.

Language: Английский

Citations

1

Design of IoT-based Volatile Organic Compounds Monitoring System DOI Open Access
Bo Wang,

Minghao Ma

Journal of Electronic Research and Application, Journal Year: 2024, Volume and Issue: 8(3), P. 161 - 171

Published: June 13, 2024

Volatile organic compounds (VOC) gas detection devices based on semiconductor sensors have become a common method due to their low cost, simple principle, and small size. However, with the continuous development of materials science, various new been applied in fabrication sensors, but these more stringent requirements for operating temperature, which cannot be met by existing sensor modules market. Therefore, this paper proposes temperature-adjustable module designs an environmental monitoring system STM32F103RET6 microprocessor. This primarily utilizes multiple monitor record concentrations harmful gases different environments. It can also real-time humidity, latitude longitude current environment, upload data Internet Things via 4G communication. has advantages size, portability, cost. Experimental results show that achieve precise control temperature certain extent, average error approximately 3%. The demonstrates level accuracy detecting target promptly cloud platform storage processing. A comparison professional testing equipment shows sensitivity curves each exhibit similarity. study provides engineering technical references application VOC sensors.

Language: Английский

Citations

0

COHERENT AMPLITUDE MODULATION IN A LASER GAS SENSOR DOI Open Access
Z. Zh. Zhanabaev

Eurasian Physical Technical Journal, Journal Year: 2023, Volume and Issue: 20(4 (46)), P. 111 - 115

Published: Dec. 19, 2023

The article is devoted to a current topic in science and technology -determining the type concentration of gas using laser. At close values green laser radiation intensity bias voltage, interference patterns time series photodiode output signal were obtained. degree coherence (more than ~0.1) made it possible distinguish between types gases their concentrations. Signal was controlled by Allan deviation values.The novelty research method choice harmonic electrical network asthe main modulation frequency. It shown that correlation functions corresponding power spectra are sensitive low-frequency fluctuations molecules clumps. This allows results methods this work be used specific cases instead large-sized expensive complexes optical instruments at room pressure temperature.

Language: Английский

Citations

0