Protein analysis using capillary electrophoresis coupled to mass spectrometry through vibrating sharp‐edge spray ionization DOI
Makenzie T. Witzel,

Lindsay M. Veltri,

Marius M. Kostelic

et al.

Electrophoresis, Journal Year: 2024, Volume and Issue: unknown

Published: April 5, 2024

Abstract Capillary electrophoresis (CE) interfaced to mass spectrometry (MS) with electrospray ionization typically incorporates acidic additives or organic solvents assist in ionization. Vibrating sharp‐edge spray (VSSI) is a voltage‐free method interface CE and MS that does not require these additives, making it appealing for protein analyses. CE–VSSI nanoflow sheath separations are performed low ionic strength aqueous solutions the reduce suppression. Serine also included analyte adduction. Proteins detected 2.5–10 µM range, corresponding an injected range of 0.1–1.2 ng. The anionic proteins β‐lactoglobulin transferrin resolved using unmodified fused silica capillary because they do exhibit nonspecific surface adsorption. Conversely, cationic cytochrome c , ribonuclease A, α‐chymotrypsinogen A background electrolytes overcome Alternatively, semipermanent coating comprised self‐assembled lipids overcomes adsorption at neutral pH. Separations zwitterionic hybrid coatings complete within 15 6 min, respectively. dimeric form triosephosphate isomerase was observed 60 µM, 19 ng, by dropping temperature inlet.

Language: Английский

Achieving Acceleration to First-in-Human: MSD’s Learnings on Platform Method Validation Strategy DOI Creative Commons

Xiaoqing Hua,

Jorge A. Quiroz,

Joop Waterval

et al.

mAbs, Journal Year: 2025, Volume and Issue: 17(1)

Published: Feb. 18, 2025

Over the past decades, number of therapeutic protein pipelines in early-phase clinical studies has increased dramatically. The rapid growth pipeline underscores need to accelerate early-stage development and enable fast first-in-human (FIH) trials bring novel therapies patients. Across industry, various efforts have been developed achieve this goal. In communication, a platform analytical method validation approach used by MSD for FIH programs is described. A case study from release panel, polysorbate 80 (PS-80) utilized illustrate workflow. approach, historical data within same modality are summarized supplemented with statistical analyses justify limited future projects. strategy reduced overall timeline up 4 months 1-2 successfully implemented filings. This communication provides insights pharmaceutical companies interested developing approaches studies.

Language: Английский

Citations

0

Recent developments of imaged capillary isoelectric focusing technology for in-depth biopharmaceutical characterization DOI Creative Commons
Bo Tao, Feng Yang, Bo Yan

et al.

TrAC Trends in Analytical Chemistry, Journal Year: 2025, Volume and Issue: unknown, P. 118212 - 118212

Published: Feb. 1, 2025

Language: Английский

Citations

0

LC-MS/MS: a powerful tool for modern analytical science: Fundamentals, techniques, applications and innovations DOI
Shivani Chaudhary,

Aarti Passi,

Shammy Jindal

et al.

Journal of Liquid Chromatography &amp Related Technologies, Journal Year: 2025, Volume and Issue: unknown, P. 1 - 11

Published: April 16, 2025

Language: Английский

Citations

0

An interlaboratory capillary zone electrophoresis‐UV study of various monoclonal antibodies, instruments, and ε‐aminocaproic acid lots DOI Creative Commons

Rebecca Wiesner,

Holger Zagst,

Wenkui Lan

et al.

Electrophoresis, Journal Year: 2023, Volume and Issue: 44(15-16), P. 1247 - 1257

Published: April 20, 2023

Capillary zone electrophoresis ultraviolet (CZE-UV) has become increasingly popular for the charge heterogeneity determination of mAbs and vaccines. The ε-aminocaproic acid (eACA) CZE-UV method been used as a rapid platform method. However, in last years, several issues have observed, example, loss electrophoretic resolution or baseline drifts. Evaluating role eACA on reported issues, various laboratories were requested to provide their routinely methods, background electrolyte compositions. Although every laboratory claimed use He et al. method, most methods actually deviate from He's. Subsequently, detailed interlaboratory study was designed wherein two commercially available (Waters' Mass Check Standard mAb [pI 7] NISTmAb 9]) provided each laboratory, along with protocols short-end, high-speed, long-end, high-resolution Ten participated using own instruments, commodities, showing excellence performance (relative standard deviations [RSDs] percent time-corrected main peak areas 0.2% 1.9%, RSDs migration times 0.7% 1.8% [n = 50 per laboratory], analysis some cases short 2.5 min). This clarified that is not reason abovementioned variations.

Language: Английский

Citations

10

Protein analysis using capillary electrophoresis coupled to mass spectrometry through vibrating sharp‐edge spray ionization DOI
Makenzie T. Witzel,

Lindsay M. Veltri,

Marius M. Kostelic

et al.

Electrophoresis, Journal Year: 2024, Volume and Issue: unknown

Published: April 5, 2024

Abstract Capillary electrophoresis (CE) interfaced to mass spectrometry (MS) with electrospray ionization typically incorporates acidic additives or organic solvents assist in ionization. Vibrating sharp‐edge spray (VSSI) is a voltage‐free method interface CE and MS that does not require these additives, making it appealing for protein analyses. CE–VSSI nanoflow sheath separations are performed low ionic strength aqueous solutions the reduce suppression. Serine also included analyte adduction. Proteins detected 2.5–10 µM range, corresponding an injected range of 0.1–1.2 ng. The anionic proteins β‐lactoglobulin transferrin resolved using unmodified fused silica capillary because they do exhibit nonspecific surface adsorption. Conversely, cationic cytochrome c , ribonuclease A, α‐chymotrypsinogen A background electrolytes overcome Alternatively, semipermanent coating comprised self‐assembled lipids overcomes adsorption at neutral pH. Separations zwitterionic hybrid coatings complete within 15 6 min, respectively. dimeric form triosephosphate isomerase was observed 60 µM, 19 ng, by dropping temperature inlet.

Language: Английский

Citations

3