Programmable DNA Templates for Silver Nanoclusters Synthesis To Develop On-Demand FRET Aptasensor
Analytical Chemistry,
Journal Year:
2024,
Volume and Issue:
96(25), P. 10391 - 10398
Published: June 6, 2024
DNA-templated
silver
nanoclusters
(AgNCs-DNA)
can
be
synthesized
via
a
one-pot
method
bypassing
the
tedious
process
of
biomolecular
labeling.
Appending
an
aptamer
to
DNA
templates
results
in
dual-functionalized
strands
that
utilized
for
synthesizing
aptamer-modified
AgNCs,
thereby
enabling
development
label-free
fluorescence
aptasensors.
However,
major
challenge
lies
necessity
redesign
strand
each
specific
target,
thus
increasing
complexity
and
hindering
widespread
application
these
To
overcome
this
challenge,
we
designed
six
(DNA1-DNA6)
incorporate
AgNCs
synthesis
A4-linker
further
coupling.
Among
all
AgNCs-DNA
samples,
it
was
found
both
AgNCs-DNA1
AgNCs-DNA2
stood
out
their
excellent
long-term
stability.
After
capturing
T4-linker
connected
with
aptamer1
aflatoxin
B1
(AFB1),
however,
only
AgNCs-DNA1/aptamer1
maintained
This
finding
highlighted
potential
as
versatile
probe
on-demand
emphasize
its
benefits
aptasensing
applications,
MoS
Language: Английский
A visual biosensor chip based on the enhanced electrochemiluminescence with low triggered potential for ochratoxin A detection
Liqi Liu,
No information about this author
Yu Qiu,
No information about this author
Yi Zou
No information about this author
et al.
Sensors and Actuators B Chemical,
Journal Year:
2024,
Volume and Issue:
420, P. 136461 - 136461
Published: Aug. 13, 2024
Language: Английский
Lectin-Mediated Labeling of Alkaline Phosphatase for Enzymatic Silver Deposition-Based Electrochemical Detection of Glycoprotein Tumor Markers
Junpeng Lv,
No information about this author
Songmin Chen,
No information about this author
Wenhui Xu
No information about this author
et al.
Analytical Chemistry,
Journal Year:
2025,
Volume and Issue:
unknown
Published: Jan. 23, 2025
The
screening
of
glycoprotein
markers
has
become
an
integral
part
the
in
vitro
diagnosis
malignant
tumors.
Herein,
electrochemical
method
based
on
alkaline
phosphatase
(ALP)-mediated
enzymatic
silver
deposition
is
reported
for
highly
sensitive
detection
tumor
markers,
which
ALP
enzymes
are
decorated
to
glycan
moieties
targets
via
lectin-carbohydrate
interactions.
As
glycoproteins
conjugated
with
multiple
chains,
lectin-mediated
labeling
can
result
decoration
each
target
enzymes.
Moreover,
hydrolysis
ascorbic
acid
2-phosphate
into
a
high
density
particles,
then
be
sensitively
assayed
robust
Ag/AgCl
solid-state
voltammetric
process.
result,
deposition-based
exhibits
sensitivity.
Using
aptamer-based
breast
cancer-associated
CA15-3
as
proof
concept,
limit
0.32
mU/mL
been
demonstrated.
Results
show
that
synergism
capture
and
glycoform-specific
discrimination
capability
interactions
endow
this
selectivity,
its
practical
use
assay
levels
serum
samples
illustrated.
With
benefits
from
efficiency,
mild
reaction
conditions,
user-friendly
operation,
applicable
low-abundance
markers.
Language: Английский
The development of electrochemiluminescent probes: Mechanism and application
Tongtong Li,
No information about this author
Yingying Su,
No information about this author
Lichun Zhang
No information about this author
et al.
Microchemical Journal,
Journal Year:
2025,
Volume and Issue:
unknown, P. 113216 - 113216
Published: March 1, 2025
Language: Английский
Advanced Electrochemiluminescence Biosensing Enabled by High-Performance Lipophilic [AuAg24(SPhMe2)18]– Nanoclusters Coupled with Bipolar Electrochemistry
Hongfei Ji,
No information about this author
Mingyue Chen,
No information about this author
Yuzhu Sun
No information about this author
et al.
Sensors and Actuators B Chemical,
Journal Year:
2025,
Volume and Issue:
unknown, P. 137840 - 137840
Published: April 1, 2025
Language: Английский
Single-Electrode Flow Cell for Electrochemiluminescent Flow Analysis
Zhiyong Dong,
No information about this author
Yequan Chen,
No information about this author
Shiyu Xia
No information about this author
et al.
Analytical Chemistry,
Journal Year:
2024,
Volume and Issue:
unknown
Published: Nov. 20, 2024
Flow
injection
analysis
and
liquid
chromatography
are
frequently
combined
with
electrochemiluminescence
(ECL)
for
flow
analysis.
Almost
all
electrochemistry
analyses
employ
traditional
three-electrode
electrochemical
cells
which
have
working
electrode,
counter
reference
electrode;
however,
it
is
expensive
difficult
to
fabricate
a
cell
inconvenient
renew
the
electrode.
In
this
study,
we
developed
single-electrode
using
commercially
available
conductive
polyethylene
film
as
only
electrode
through
potential
differences
induced
by
resistance
first
time.
The
features
simple
structure,
easy
renewal
of
low
cost
compared
cells.
Taking
typical
Ru(bpy)
Language: Английский