Bisimidazole ionic liquid functionalized ZIF-8 solid-phase extraction coupled with high performance liquid chromatography for analysis Rhodamine B in food samples DOI Creative Commons
Xiashi Zhu,

Shuyu Wan,

Ouwen Xu

et al.

Research Square (Research Square), Journal Year: 2022, Volume and Issue: unknown

Published: Aug. 12, 2022

Abstract An effective method based on the bisimidazole ionic liquid functionalized ZIF-8 solid-phase extractant (ZIF-8@MIM-MIM) coupled with high performance chromatography (HPLC) for separation/analysis of Rhodamine B was established. ZIF-8@MIM-MIM characterized by FTIR, XRD, SEM and TEM. Several important factors, such as pH, amount extractant, extract time types eluents were investigated in detail. Under optimal conditions, linear range 0.02-40.00 µg mL − 1 , detection limit 7.0 ng correlation good (R 2 = 0.9986). The chili powder, red wine, plum juice strawberry jam proved that simple effective, could be used to separate analyze real samples.

Language: Английский

Graphene and MOF Assembly: Enhanced Fabrication and Functional Derivative via MOF Amorphization DOI Creative Commons
Zeheng Lin, Zhaojun Han, George E. P. O'Connell

et al.

Advanced Materials, Journal Year: 2024, Volume and Issue: 36(19)

Published: Jan. 30, 2024

Abstract The integration of graphene and metal–organic frameworks (MOFs) has numerous implications across various domains, but fabricating such assemblies is often complicated time‐consuming. Herein, a one‐step preparation graphene‐MOF assembly presented by directly impregnating vertical (VG) arrays into the zeolitic imidazolate framework (ZIF) precursors under ambient conditions. This approach can effectively assemble multiple ZIFs, including ZIF‐7, ZIF‐8, ZIF‐67, resulting in their uniform dispersion on VG with adjustable sizes shapes. Hydrogen defects surface are critical inducing high‐efficiency ZIF assembly, acting as reactive sites to interact facilitate crystallisation. versatility VG‐ZIF‐67 further demonstrated exploring process MOF amorphization. Surprisingly, this leads an amorphous thin‐film coating formed (named VG‐IL‐amZIF‐67), which preserves short‐range molecular bonds crystalline ZIF‐67 while sacrificing long‐range order. Such unique film‐on‐graphene architecture maintains essential characteristics functionalities within disordered arrangement, making it well‐suited for electrocatalysis. In electrochemical oxygen reduction, VG‐IL‐amZIF‐67 exhibits exceptional activity, selectivity, stability produce H 2 O acid media.

Language: Английский

Citations

18

dl-carnitine-based green hydrophobic deep eutectic solvent for the enrichment of bisphenol A in mineral water based on ultrasound-assisted liquid-phase microextraction DOI
Fatemeh Mehrabi, Mehrorang Ghaedi, Ebrahim Alipanahpour Dil

et al.

Talanta, Journal Year: 2023, Volume and Issue: 266, P. 125045 - 125045

Published: Aug. 19, 2023

Language: Английский

Citations

20

Enhancing the photoelectric performance of TiO2-based heterojunction using the hydrothermal decomposition of MIL-125 strategy for sensitive detection of Bisphenol A DOI

Shaohui Yu,

Haizhong Lin,

Xiaoshan Liu

et al.

Sensors and Actuators B Chemical, Journal Year: 2024, Volume and Issue: 413, P. 135881 - 135881

Published: May 1, 2024

Language: Английский

Citations

6

Target-regulated photoactivities of CdS/Ni-MOF heterojunction with [Ru(bpy)2dppz]2+ intercalator: a bisphenol A photoelectrochemical aptasensor DOI

Aisyah Protonia Tanjung,

Ke Yin,

Lei Zhao

et al.

Microchimica Acta, Journal Year: 2024, Volume and Issue: 191(3)

Published: Feb. 16, 2024

Language: Английский

Citations

5

VOLTAMMETRIC INVESTIGATION OF SYNTHESIZED ZIRCONIUM OXIDE NANOPARTICLES FOR DETECTION OF CATECHOL DOI

Bindu A. G,

Ramesh S. Bhat

Journal of environmental chemical engineering, Journal Year: 2025, Volume and Issue: unknown, P. 116046 - 116046

Published: March 1, 2025

Language: Английский

Citations

0

Advanced ZnFe₂O₄@f-CNF electrode: A robust electrochemical sensor for Tert-butyl hydroquinone detection in food and edible oil DOI
Rajeshwari Yemmi, B.E. Kumara Swamy,

Kumbar Mudakappa Manjunath

et al.

Food Chemistry, Journal Year: 2025, Volume and Issue: 486, P. 144648 - 144648

Published: May 6, 2025

Language: Английский

Citations

0

Water-based green deep eutectic solvent: application in liquid–liquid microextraction of trace bisphenol A in edible oils DOI
Yanling Hao, Bin Huo,

Fangyu Wang

et al.

Talanta, Journal Year: 2024, Volume and Issue: 286, P. 127511 - 127511

Published: Dec. 31, 2024

Language: Английский

Citations

3

Molecularly imprinted polymers in zeolitic imidazolate frameworks: A comprehensive review DOI
Ali Bakhshi, Mehrdad Roshan,

Mohammad Asgari

et al.

Coordination Chemistry Reviews, Journal Year: 2025, Volume and Issue: 534, P. 216561 - 216561

Published: March 14, 2025

Language: Английский

Citations

0

A fluorescent method for bisphenol A detection based on enzymatic oxidation-mediated emission quenching of silicon nanoparticles DOI
Shi Gang Liu,

Tiankang Wu,

Zhixin Liang

et al.

Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy, Journal Year: 2023, Volume and Issue: 302, P. 123123 - 123123

Published: July 8, 2023

Language: Английский

Citations

7

A dual-mode “signal-on” split-type aptasensor for bisphenol A via target-induced hybridization chain reaction amplification DOI

You Wu,

Zheng Wang, Jing Li

et al.

The Analyst, Journal Year: 2023, Volume and Issue: 148(24), P. 6297 - 6305

Published: Jan. 1, 2023

Herein, a dual-mode detection system was constructed for efficient and accurate of bisphenol A (BPA) with the assistance BPA-induced hybridization chain reaction (HCR). The captured DNA (cDNA) first modified on surface magnetic spheres gold nanoparticles polydopamine then hybridized BPA aptamer to form double-stranded (dsDNA). In presence target, released from sphere. free cDNA triggered HCR construct duplex. Methylene blue (MB), as bifunctional probe, intercalated into amplify photocurrent (IPEC) CdS-modified electrode generate an electrochemical current (IEC) at same time. Under optimized conditions, PEC EC signal responses were linear logarithm concentration in range 1.0 × 10-10 M 10-5 M. limits found be 1.27 10-11 3.0 using methods, respectively. biosensor exhibited good performance real sample analysis, demonstrating its promising potential practical applications. addition, this strategy provides more reliable results.

Language: Английский

Citations

7