Energy Systems, Journal Year: 2024, Volume and Issue: unknown
Published: Dec. 17, 2024
Language: Английский
Energy Systems, Journal Year: 2024, Volume and Issue: unknown
Published: Dec. 17, 2024
Language: Английский
Science Progress, Journal Year: 2025, Volume and Issue: 108(1)
Published: Jan. 1, 2025
Current power networks face considerable issues due to a continuous decrease in inertia and increased sensitivity load/generation fluctuations. The main cause of these problems is the enhanced penetration capabilities renewable energy sources. An unbalanced load with high output greatly affects frequency behavior electrical grids. Several load-frequency control mechanisms are commonly employed tackle problems. Accordingly, purpose this work present novel optimal methodology for dual-area-linked systems that contain variety conventional (i.e. thermal generator) solar photovoltaic plant) A revolutionary hybrid regulator, one plus proportional integral double-integral derivative fractional filter (1 + PIID-PD μ F λ ), has been designed. Its goal lessen drifts brought on by any known disturbance. gains 1 controller finely adjusted using mother optimization algorithm, an up-to-date population-based metaheuristic technique simulates procedure birthing growth. algorithm demonstrated its superior performance compared other brand-new methods, including tuna swarm sea horse optimization. effectiveness proposed algorithm-based regulator assessed comparing cascaded regulators existing literature, such as TIDF-PID D, FOPI-PIDA, PID-TID, which stand tilt filter-proportional filter, integral-proportional acceleration, derivative-tilted derivative, respectively. Various scenarios involving fluctuations (step, multi-step, random), radiation changes, system parameter modifications used demonstrate controller's handling disturbances. simulation results, presented MATLAB/SIMULINK, show outperforms controllers terms dynamic response disturbances, namely it achieved substantial reduction overshoot (94.66%, 48.49%, 68.75%), undershoot 26.75%, 67.25%), settling time (78.57%, 90.81%, 75.0%) measured deviation Area 1, Similar improvements were observed 2 exchange between areas.
Language: Английский
Citations
0Neurocomputing, Journal Year: 2025, Volume and Issue: unknown, P. 130123 - 130123
Published: March 1, 2025
Language: Английский
Citations
0Scientific Reports, Journal Year: 2025, Volume and Issue: 15(1)
Published: May 19, 2025
Language: Английский
Citations
0Journal of Energy Storage, Journal Year: 2024, Volume and Issue: 106, P. 114582 - 114582
Published: Nov. 28, 2024
Language: Английский
Citations
0Energy Systems, Journal Year: 2024, Volume and Issue: unknown
Published: Dec. 17, 2024
Language: Английский
Citations
0