Negative dysphotopsia DOI Creative Commons

Natalia Y. Makhotkina

Published: Jan. 1, 2024

Case series AQ5010V, Clariflex 8/11 (73) report Rayner Sulcoflex 653T 1/1 (100) 653L 7/9 (78) LI61AO 2/3 (67) 1stQ Addon (77) 653 MP, Ar40e 2/2 MA60AC 5/5 AQ2010V CQ2015A, 7/8 (88) 0/1 (0) CN60CM S122UV 1/2 2011, 2018 AQ2010V, SI40NB, CC4204A 0/5 18/18 ovoid Softec HDO 10/10 ZA9993, Artisan Afakia 9/11 (82) -0/1 Chapter 2 Effect of active evaluation on the detection negative dysphotopsia after sequential cataract surgery: discrepancy between incidences unsolicited and solicited complaints.

Language: Английский

Two novel extended depth-of-focus intraocular lenses targeted for mini-monovision: a prospective randomized controlled trial DOI Creative Commons
Joukje C. Wanten,

Noël J.C. Bauer,

Tos T. J. M. Berendschot

et al.

American Journal of Ophthalmology, Journal Year: 2025, Volume and Issue: unknown

Published: April 1, 2025

To compare the visual outcomes of two extended depth-of-focus (EDOF) intraocular lenses (IOLs). Single-center prospective randomized controlled trial. Patients undergoing bilateral cataract surgery were randomly assigned to receive either Acunex Vario IOL (Teleon Surgical B.V., Spankeren, The Netherlands) or AcrySof IQ Vivity (Alcon, Geneva, Switzerland); both Vario- and Vivity-group targeted for mini-monovision. primary outcome was uncorrected intermediate acuity (UIVA, measured at 66cm). Secondary parameters distance (UDVA), near (UNVA), defocus curves, reading speed, contrast sensitivity, spectacle independence quality vision. University Eye Clinic, Maastricht Medical Center+, Netherlands. A total 31 subjects (62 eyes) included, 16 patients enrolled into Vario-group 15 Vivity-group. At three months postoperatively, no statistically significant differences found binocular acuities between groups after adjustment covariates. mean standard deviation UIVA 0.04±0.11 0.15±0.11 logMAR (adjusted-P=0.264) Vivity-group, respectively. UDVA 0.00±0.14 0.08±0.10 (adjusted-P=0.753), UNVA 0.22±0.17 0.31±0.14 (adjusted-P=0.235), groups, While had a larger range defocus, patient satisfaction independence. Contrast sensitivity speed comparable, there in optical side effects groups. Bilateral implantation mini-monovision comparable results outcomes, effects, speed. showed continuous defocus.

Language: Английский

Citations

0

Preliminary Visual Outcomes of a Novel Non-Diffractive Extended Monofocal Intraocular Lens (Evolux) 3 Months After Cataract Surgery DOI Open Access
Laura Denisa Preoteasa,

Ramona Barac,

D Preoteasa

et al.

Journal of Clinical & Translational Ophthalmology, Journal Year: 2024, Volume and Issue: 2(4), P. 171 - 180

Published: Dec. 5, 2024

Background: This study aims to evaluate the visual performance, both quantitative and qualitative, of novel non-diffractive extended monofocal intraocular lens (Evolux, Sifi) following cataract surgery. serves as a preliminary assess its feasibility improve research methodology. Methods: We conducted single-arm, non-randomized, retrospective at Onioptic Hospital, Craiova, Romania, involving patients who underwent surgery from November 2022 August 2023. The parameters were evaluated 3 months postoperatively: monocular uncorrected (UDVA) corrected (CDVA) distance acuity 4 m; (UIVA) distance-corrected (DCIVA) intermediate 60 cm; (UNVA) (DCNVA) near 40cm; postoperative refraction expressed spheric equivalent (SE) Quality Vision (QoV) questionnaire scores. contrast sensitivity defocus curve 1 month postoperation in 22 eyes. SPSS Statistics 26.0 was used for statistical analysis, employing percentages, standard deviations (SDs), 95% confidence interval (95% CI). Results: Among 103 eyes 81 (mean age 68.7 ± 1.845), 64% achieved an UDVA logMAR 0.1 or better, 91.26% CDVA better months. Additionally, 83.24% exhibited UIVA 0.3 60.19% attained UNVA better. SE within ±0.50 D 77.76% QoV mean scores follows: frequency = 30.20 16; severity 17.19 12.45; bothersome 15.45 12.94. Conclusions: Evolux IOL demonstrated very good biometric predictability excellent performance vision, with no photopic side effects glare our sample population. provides strong foundation larger comparative depth-of-focus (EDOF) IOL, incorporating assessments enhance quality.

Language: Английский

Citations

0

Negative dysphotopsia DOI Creative Commons

Natalia Y. Makhotkina

Published: Jan. 1, 2024

Case series AQ5010V, Clariflex 8/11 (73) report Rayner Sulcoflex 653T 1/1 (100) 653L 7/9 (78) LI61AO 2/3 (67) 1stQ Addon (77) 653 MP, Ar40e 2/2 MA60AC 5/5 AQ2010V CQ2015A, 7/8 (88) 0/1 (0) CN60CM S122UV 1/2 2011, 2018 AQ2010V, SI40NB, CC4204A 0/5 18/18 ovoid Softec HDO 10/10 ZA9993, Artisan Afakia 9/11 (82) -0/1 Chapter 2 Effect of active evaluation on the detection negative dysphotopsia after sequential cataract surgery: discrepancy between incidences unsolicited and solicited complaints.

Language: Английский

Citations

0