Retrofit Analysis of Exterior Windows for Large Office Buildings in Different Climate Zones of China DOI Creative Commons
Sai Liu, Farid Ezanee Mohamed Ghazali, H. J. Yang

et al.

Buildings, Journal Year: 2024, Volume and Issue: 14(12), P. 3904 - 3904

Published: Dec. 6, 2024

In the energy-saving retrofit of existing buildings, investors are particularly concerned about performance exterior windows and payback period additional costs. This study evaluates representative cities in four different climate zones China to simulate energy consumption large office buildings after replacing glass conducting economic feasibility assessments. The research method includes following steps: First, a baseline model was established using AutoBPS OpenStudio. Then, models were simulated EnergyPlus V9.3.0 obtain multiple hourly results. commercial electricity gas prices adjusted calculate total cost within 20 years types windows. Using discounted (DPP), net present value (NPV), profitability index (PI) as evaluation indicators, analysis conducted regions evaluate building simulation results show that considering meeting standards, it is more economical choose with moderate U-value SHGC than smallest value, both savings benefits closely related age, older (especially those Changsha Shenzhen) showing greater benefits. Furthermore, optimal window determined this can recover investment life, Harbin (SC), Beijing (C), (HC), Shenzhen (HW) 6.60, 15.66, 10.16, 11.42 years, respectively. provides useful path for selecting data support decision making investors.

Language: Английский

Transparent superhydrophobic and thermal insulating dual‐functional coatings fabricated by a rapid thermal process DOI Open Access

Chong Ke,

Chenhua Zhang,

Liquan Pan

et al.

International Journal of Applied Ceramic Technology, Journal Year: 2025, Volume and Issue: unknown

Published: March 29, 2025

Abstract Superhydrophobic coatings with a thermal insulation property were fabricated via rapid process. In brief, coating solutions containing low‐melting‐point glass powder, antimony‐doped tin oxide nanopowder, and other additives first applied to substrates. Subsequently, the coated samples underwent process in tube furnace at 690°C for 2 min. The relationship between nanopowder content coatings’ performance was examined systematically. hydrophobic properties measured their morphology, phase, surface roughness characterized. optimized has water contact angle of 154°, demonstrating its superhydrophobicity. infrared transmittance optimal sample 780 2500 nm is reduced by 13.3%, after being exposed an lamp 5 min, temperature below 4.7°C lower, compared bare substrate, showing dual functionalities prepared samples. Moreover, since can be achieved conventional tempering process, fabrication this simple readily realized.

Language: Английский

Citations

0

Electrochromic smart window supercapacitor based on a hyperbranched electroactive polyamide for sustainable buildings DOI
Yunfei Xie,

Meini Li,

Junru Chen

et al.

Journal of Colloid and Interface Science, Journal Year: 2025, Volume and Issue: 693, P. 137592 - 137592

Published: April 12, 2025

Language: Английский

Citations

0

BIM-based parametric energy analysis of green building components for the roofs and facades DOI Creative Commons

Felippe Pereira Ribeiro,

Olubimbola Oladimeji, Marcos Barreto de Mendonça

et al.

Next Sustainability, Journal Year: 2024, Volume and Issue: 5, P. 100078 - 100078

Published: Oct. 7, 2024

Language: Английский

Citations

3

Retrofit Analysis of Exterior Windows for Large Office Buildings in Different Climate Zones of China DOI Creative Commons
Sai Liu, Farid Ezanee Mohamed Ghazali, H. J. Yang

et al.

Buildings, Journal Year: 2024, Volume and Issue: 14(12), P. 3904 - 3904

Published: Dec. 6, 2024

In the energy-saving retrofit of existing buildings, investors are particularly concerned about performance exterior windows and payback period additional costs. This study evaluates representative cities in four different climate zones China to simulate energy consumption large office buildings after replacing glass conducting economic feasibility assessments. The research method includes following steps: First, a baseline model was established using AutoBPS OpenStudio. Then, models were simulated EnergyPlus V9.3.0 obtain multiple hourly results. commercial electricity gas prices adjusted calculate total cost within 20 years types windows. Using discounted (DPP), net present value (NPV), profitability index (PI) as evaluation indicators, analysis conducted regions evaluate building simulation results show that considering meeting standards, it is more economical choose with moderate U-value SHGC than smallest value, both savings benefits closely related age, older (especially those Changsha Shenzhen) showing greater benefits. Furthermore, optimal window determined this can recover investment life, Harbin (SC), Beijing (C), (HC), Shenzhen (HW) 6.60, 15.66, 10.16, 11.42 years, respectively. provides useful path for selecting data support decision making investors.

Language: Английский

Citations

0