Construction and biocompatibility evaluation of CS-FA/VA composite coating on the surface of ZE21B vascular stent DOI
Yi Ma, Jingan Li, Yifan Zhou

et al.

Applied Surface Science, Journal Year: 2024, Volume and Issue: 681, P. 161413 - 161413

Published: Oct. 11, 2024

Language: Английский

Three-Dimensional Printed Cardiac Models Demonstrating Extensive Cardiac Calcification Assist in Preprocedural Planning DOI

Ross Foley,

Kevin Walsh, Eoin D. O’Cearbhaill

et al.

World Journal for Pediatric and Congenital Heart Surgery, Journal Year: 2025, Volume and Issue: unknown

Published: Feb. 6, 2025

Cardiac calcification is common in adults with congenital heart disease, typically affecting surgical sites and prosthetic material. Understanding the precise location degree of important during decision-making process prior to possible intervention but can be difficult determine different imaging modalities. Advances three-dimensional (3D) modeling printing have made it distinguish tissue types accurately display them colors on printed models. We present two adult disease patients where advanced 3D was used demonstrate cardiac aided preprocedural planning process.

Language: Английский

Citations

0

Coronary Intravascular Lithotripsy Effectiveness and Safety in a Real-World Cohort DOI Open Access
Catarina Oliveira,

Marta Vilela,

Miguel Nobre Menezes

et al.

Journal of Personalized Medicine, Journal Year: 2024, Volume and Issue: 14(4), P. 438 - 438

Published: April 22, 2024

Background: Coronary artery calcification is a predictor of adverse outcomes after percutaneous coronary intervention (PCI). Intravascular lithotripsy (IVL) promising tool for the treatment calcified lesions. The aim this study was to assess effectiveness and safety IVL. Methods: A single-center observational PCI procedure, with assessment patients undergoing using IVL, performed. Angiographic procedural success used as primary endpoint. endpoint defined composite cardiac death, myocardial infarction target vessel revascularization within 30 days. Results: total 111 were included. Indications spanned spectrum chronic (53.2%) acute syndromes (43%). Lesion preparation before IVL performed non-compliant (42%), cutting or OPN (14.4%) balloons atherectomy techniques in 11% procedures. imaging 21.6% achieved 100% 3.6% Peri-procedural complications minimal successfully resolved. Conclusions: an effective safe technique These findings contribute growing body evidence supporting use management these challenging scenarios.

Language: Английский

Citations

2

Construction and biocompatibility evaluation of CS-FA/VA composite coating on the surface of ZE21B vascular stent DOI
Yi Ma, Jingan Li, Yifan Zhou

et al.

Applied Surface Science, Journal Year: 2024, Volume and Issue: 681, P. 161413 - 161413

Published: Oct. 11, 2024

Language: Английский

Citations

1