A Microscopy Evaluation of Emergence Profile Surfaces of Dental Custom CAD-CAM Implant Abutments and Dental Implant Stock Abutments DOI Open Access

Daniel Adrian Ţârtea,

Horia Octavian Manolea, Mihaela Ionescu

et al.

Journal of Personalized Medicine, Journal Year: 2024, Volume and Issue: 14(7), P. 699 - 699

Published: June 28, 2024

Recently, due to the high demand for dental implants, use of implant stock abutments has increased significantly, especially custom CAD/CAM milled by technicians in their laboratories. The purpose this study is analyze surface quality emergence profile made a non-industrial milling machine, compared original and compatible industrial machines. Thirty were divided into six lots. Lot 1 (control group): abutments-industrial machined; lot 2 (study lots 3, 4, 5, 6 groups): abutments-non-industrial with hyperDENT CAM software Paragon Tools. Nikon SMZ745T stereomicroscope was used each abutment. structure analyzed surfaces did not show significant differences between that industrially machined. As customized abutments, greatest similarity obtained 6, statistical difference 4. Stepover Feed Rate parameters process influenced roughness abutments. digital technology reliable within correct parameters.

Language: Английский

PEEK for Oral Applications: Recent Advances in Mechanical and Adhesive Properties DOI Open Access

Chengfeng Luo,

Ying Liu, Bo Peng

et al.

Polymers, Journal Year: 2023, Volume and Issue: 15(2), P. 386 - 386

Published: Jan. 11, 2023

Polyetheretherketone (PEEK) is a thermoplastic material widely used in engineering applications due to its good biomechanical properties and high temperature stability. Compared traditional metal ceramic dental materials, PEEK implants exhibit less stress shielding, thus better matching the mechanical of bone. As promising medical material, can be as implant abutments, removable fixed prostheses, maxillofacial prostheses. It blended with materials such fibers ceramics improve strength for clinical applications. conventional pressed CAD/CAM milling fabrication, 3D-printed exhibits excellent flexural tensile parameters printing speed affect properties. However, bioinert nature make adhesive bonding difficult. The bond improved by roughening or introducing functional groups on surface sandblasting, acid etching, plasma treatment, laser systems. This paper provides comprehensive overview research progress context specific applications, composites, their preparation processes. In addition, over past few years highlighted. Thus, this review aims build conceptual practical toolkit study materials. More importantly, it rationale general new basis application field.

Language: Английский

Citations

82

Biomaterials and Clinical Application of Dental Implants in Relation to Bone Density—A Narrative Review DOI Open Access
Angkoon Khaohoen, Tanapon Sornsuwan,

Pisaisit Chaijareenont

et al.

Journal of Clinical Medicine, Journal Year: 2023, Volume and Issue: 12(21), P. 6924 - 6924

Published: Nov. 3, 2023

Titanium has been the material of choice for dental implant fixtures due to its exceptional qualities, such as excellent balance rigidity and stiffness. Since zirconia is a soft-tissue-friendly caters esthetic demands, it an alternative titanium use in implants. Nevertheless, bone density plays vital role determining design Compromised leads both early late failures lack stability. Therefore, this narrative review aims investigate influence material/design surgical technique on from biomechanical biological standpoints. Relevant articles were included analysis. Dental materials can be fabricated titanium, zirconia, PEEK. In terms mechanical aspects, still gold standard materials. Additionally, macro- microgeometry implants play planning appropriate treatment because enhance stress transmitted tissue. Under low-density conditions, conical design, longer length, large diameter, reverse buttress with self-tapping, small thread pitch, deep depth are recommended. Implant material, techniques, pivotal factors affecting success rates placement bone. Further study required find optimal clinical setting's state.

Language: Английский

Citations

29

Effect of Customized and Prefabricated Healing Abutments on Peri-Implant Soft Tissue and Bone in Immediate Implant Sites: A Randomized Controlled Trial DOI Open Access

Parima Chokaree,

Pongsakorn Poovarodom,

Pisaisit Chaijareenont

et al.

Journal of Clinical Medicine, Journal Year: 2024, Volume and Issue: 13(3), P. 886 - 886

Published: Feb. 2, 2024

This study aimed to evaluate the effect of customized healing abutments compared prefabricated in immediate implant sites. Twelve patients requiring single placement were divided into two groups: a group received titanium abutments, and polyetheretherketone (PEEK) fabricated based on individuals’ digital impressions. Outcomes, including peri-implant horizontal vertical soft tissue alteration, bone level change, volume pain score, pink esthetic score (PES) evaluated at 1-, 4-, 6-month follow-ups pre-extraction teeth. At 1- 4-month follow-ups, had significantly lower buccal variation (BVv). follow-up, neither showed any significant difference marginal change; however, PES change score. In anterior premolar regions, preservation volume, while molar papilla height midfacial was observed. The morphology abutment demonstrated better trend tissue, outcomes, patient discomfort

Language: Английский

Citations

8

Comparison of Plaque Accumulation Between Titanium and PEEK Healing Abutments DOI Creative Commons
Suphachai Suphangul,

Patr Pujarern,

Dinesh Rokaya

et al.

Journal of Functional Biomaterials, Journal Year: 2024, Volume and Issue: 15(11), P. 334 - 334

Published: Nov. 7, 2024

Titanium (Ti) is considered the gold standard material for provisional implant restorations. Polyetheretherketone (PEEK), a polymeric thermoplastic material, has been progressively used in prosthetic, restorative, and dentistry. Recently, PEEK dentistry as restoration. Plaque accumulation biofilm formation become major concerns when infection inflammation occur peri-implant tissue. Few reports were studied regarding on surface. This study aimed to compare plaque between Ti healing abutments. In an vitro setting, abutment subjected formation; result was collected after 24 h, 48 72 7 days. Biofilms following staining with crystal violet. The data analyzed by Two-Way ANOVA. It found that materials, surface slightly higher than Ti, but no statistical difference (

Language: Английский

Citations

5

Bond Strength of Sandblasted PEEK with Dental Methyl Methacrylate-Based Cement or Composite-Based Resin Cement DOI Open Access

Kentaro Hata,

Yuya Komagata,

Yuki Nagamatsu

et al.

Polymers, Journal Year: 2023, Volume and Issue: 15(8), P. 1830 - 1830

Published: April 9, 2023

Poly-ether-ether-ketone (PEEK) is commonly employed in dental prostheses owing to its excellent mechanical properties; however, it limited by low bond strength with resin cement. This study aimed clarify the type of cement most suitable for bonding PEEK: methyl methacrylate (MMA)-based or composite-based For this purpose, two MMA-based cements (Super-Bond EX and MULTIBOND II) five (Block HC Cem, RelyX Universal Resin Cement, G-CEM LinkForce, Panavia V5, Multilink Automix) were used combination appropriate adhesive primers. A PEEK block (SHOFU PEEK) was initially cut, polished, sandblasted alumina. The then bonded primer according manufacturer’s instructions. resulting specimens immersed water at 37 °C 24 h, followed thermocycling. Subsequently, tensile strengths (TBSs) measured; TBSs after thermocycling found be zero (G-CEM Automix), 0.03 ± 0.04 (RelyX Cement), 1.6 2.7 Cem), whereas those Super-Bond 11.9 2.6 4.8 2.3 MPa, respectively. results demonstrated that exhibited stronger than cements.

Language: Английский

Citations

11

Immediate Implant and Customized Healing Abutment for a Periodontally Compromised Socket: 1-Year Follow-Up Retrospective Evaluation DOI Open Access
Giovanni Battista Menchini-Fabris, Saverio Cosola, Paolo Toti

et al.

Journal of Clinical Medicine, Journal Year: 2023, Volume and Issue: 12(8), P. 2783 - 2783

Published: April 9, 2023

Immediate dental implant placement with or without immediate loading is reported in daily dentistry and implantology, but these procedures are not common the case of periradicular periapical lesions around tooth needed to be replaced. In following retrospective evaluation, 10 cases a 1-year follow-up were selected propose technique an provisional non-loading prosthesis being delivered on same day post-extraction multiradicular teeth affected by chronic lesions. Post-extractive sockets underwent filling empty space sterile, re-absorbable gelatin sponges. The widths alveolar ridge measured three-dimensional radiographs before after operation, 4 12 months later. Non-parametric statistics performed compare outcomes over time level significance 0.05. Comparing preoperative cross-sectional images cone beam computerized tomography (CBCT) scans postoperative ones, it was noted that changes crestal width, ΔCW, (compared baseline) negligible clinically appreciable. However, while ΔCW at appeared negative (−0.17 ± 045 mm), width as baseline (ΔCW = 0.02 0.48 significant difference between (p-value 0.0494). customized healing abutment polyether-ether-ketone placed into post-extractive asymptomatic large could represent further treatment strategy for patients’ rehabilitation soft tissue preservation replace hopeless tooth.

Language: Английский

Citations

11

Chemical and Structural Assessment of New Dental Composites with Graphene Exposed to Staining Agents DOI Creative Commons
Mărioara Moldovan, Diana Dudea, Stanca Cuc

et al.

Journal of Functional Biomaterials, Journal Year: 2023, Volume and Issue: 14(3), P. 163 - 163

Published: March 17, 2023

Among the newest trends in dental composites is use of graphene oxide (GO) nanoparticles to assure better cohesion composite and superior properties. Our research used GO enhance several hydroxyapatite (HA) nanofiller distribution three experimental CC, GS, GZ exposed coffee red wine staining environments. The presence silane A-174 on filler surface was evidenced by FT-IR spectroscopy. Experimental were characterized through color stability after 30 days coffee, sorption solubility distilled water artificial saliva. Surface properties measured optical profilometry scanning electron microscopy, respectively, antibacterial wer e assessed against Staphylococcus aureus Escherichia coli. A colour test revealed best results for followed GZ, with less CC. Topographical morphological aspects a synergism between sample components that conducted lower roughness, GS sample. However, roughness variation due stain affected than at macroscopic level. Antibacterial testing good effect moderate

Language: Английский

Citations

10

Peri-implant soft tissue conditioning of immediate posterior implants by CAD-CAM socket sealing abutments: a randomized clinical trial DOI Creative Commons

Mai Mohamed Elgendi,

Iman Salah El Din Hamdy, Hanaa Sallam

et al.

BMC Oral Health, Journal Year: 2025, Volume and Issue: 25(1)

Published: Jan. 17, 2025

Anatomically formed healing abutments were suggested in literature to address many of the issues associated with immediate posterior implant insertion such as large extraction sockets that are extremely hard seal without reflecting mucoperiosteal flap, anatomy not suitable for regular abutment placement, and potentially high occlusal stresses when planning a temporary supported prothesis improve conditioning supra tissue architecture emergence profile restorations. To clinically evaluate peri-implant soft single retained restorations assess patient related outcomes conditioned immediately by CAD-CAM socket sealing (SSA) versus those Titanium (Ti) standard (SHA). Twenty participants received twenty-two maxillary implants after flapless minimally invasive tooth 3D guided placement area (premolar molar) allocated randomly into two groups (n = 11), intervention group: patients PEEK SSA control Ti SHA. Modified Pink Esthetic Score (PES) was evaluated at 3 observation periods: Baseline T0 (immediate crown insertion), 6 months T1 1 year clinical performance T2. Patient satisfaction assessed one week using visual analogue scale (VAS). At base line, six well 12 months, group showed statistically significant higher total modified PES scores than SHA (P-value < 0.001). 2 periods (baseline year), significantly overall score After period, together provided superior compared terms profile. This study registered on clinicaltrials.gov ID no. NCT05276765 03/03/2022.

Language: Английский

Citations

0

Applications, modifications, and manufacturing of polyetheretherketone (PEEK) in dental implantology: A comprehensive critical review DOI
Ahmed Yaseen Alqutaibi, Mohammed Ahmed Alghauli, Radwan Algabri

et al.

International Materials Reviews, Journal Year: 2025, Volume and Issue: unknown

Published: Feb. 13, 2025

Polyetheretherketone (PEEK), a thermoplastic polymer from the polyaryletherketone (PAEK) family, is increasingly used in dental biomedical applications because of its bioinert properties. This comprehensive review examines PEEK's suitability as implant fixture and other related prostheses, focusing on mechanical stability, chemical resistance, compatibility with human bone. ability to distribute transmit occlusal forces surrounding bone, along aesthetic advantages, make it promising material that outperforms titanium zirconia. PEEK has been successfully employed various implantology applications, including fixtures, abutments, scan bodies, abutment screws, implant-supported superstructures such frameworks, crowns, bridges, well overdenture attachment components. As fixture, undergone several modifications enhance surface, mechanical, biological exhibits comparable strength materials but offers advantages reduced production times costs, improved toughness, recyclability. Its non-interference MRI CBCT enhances diagnostic capabilities, while bioactive substances like hydroxyapatite further applications. Several manufacturing methods are available, each specific limitations. Computer Numerical Control (CNC) milling commonly labs leads waste tool wear challenges. Advances micro-milling cutting technology enable finer detail parts. Additionally, 3-D printing emerging for more precise efficient part production. aims update current knowledge about modifications, field implantology. Moreover, explores challenges suggests future research directions optimising bioactivity stress distribution.

Language: Английский

Citations

0

Socket Shield Technique of an Ailing Mandibular Molar With Customized Healing Abutment: Graftless Management of the Hard and Soft Tissue Foundation Around Immediate Dental Implants DOI Creative Commons
Sanjay Kumar Sah

Case Reports in Dentistry, Journal Year: 2025, Volume and Issue: 2025(1)

Published: Jan. 1, 2025

It is an established fact that postextraction ridge resorptive changes are inevitable and very evident in the molar areas. Resorption sites can cause a reduction attached gingiva affect long-term success of osseointegrated implant. To prevent significant tissue alteration, socket shield technique (SST) was developed to preserve buccal plate, over decade ago. Since then, various studies showcasing modifications have been published mainly focusing on SST conjunction with immediate implants anterior esthetic zone. Gluckman gave collective term called partial extraction therapy (PET) which includes SST, pontic technique, root submergence technique. He suggested using graft material gap between Later, Siormpas et al. advocated membrane (RMT) it may not be necessary use material. With evolution terms RMT more similar each other now, only difference sequence preparation implant placement. The prepared first, osteotomy done former before latter. often ignored as possibility sites. Though technique-sensitive, molars customized healing abutment ensures maintenance original hard soft volumes most conservative way. following case report showcases stepwise, graftless management approach for nonrestorable right mandibular Long-term randomized controlled trials (RCTs) encouraged make recommendation routine clinical practice.

Language: Английский

Citations

0