Ag-coated Au nanostar-Based Lateral Flow Immunoassay for Highly Sensitive Influenza A virus antibody Detection in Colorimetric and Surface-Enhanced Raman Scattering (SERS) modes
Jingwen Li,
No information about this author
Min Liu,
No information about this author
Jinyue Zhu
No information about this author
et al.
Talanta,
Journal Year:
2024,
Volume and Issue:
285, P. 127351 - 127351
Published: Dec. 6, 2024
Language: Английский
pH-sensitive oligopeptide magnetic mesoporous silica beads for deoxyribonucleic acid extraction
Nanoscale Advances,
Journal Year:
2025,
Volume and Issue:
unknown
Published: Jan. 1, 2025
pH-Sensitive
oligopeptide
magnetic
mesoporous
silica
beads
were
successfully
prepared
by
using
large-pore
dendritic
colloids
as
templates
for
DNA
extraction.
Language: Английский
Magnetic nanoprobe-enabled lateral flow assays in the applications of food safety and in vitro diagnostic
Shipeng Gao,
No information about this author
Xueyun Zheng,
No information about this author
Junyong Zhu
No information about this author
et al.
Coordination Chemistry Reviews,
Journal Year:
2025,
Volume and Issue:
534, P. 216588 - 216588
Published: March 9, 2025
Language: Английский
Dual readout biosensor based on AIE-type immunomagnetic ZIF-8: from sample pretreatment to multi-residue detection
Shuai Zhang,
No information about this author
Jincheng Xiong,
No information about this author
Boyan Sun
No information about this author
et al.
Sensors and Actuators B Chemical,
Journal Year:
2025,
Volume and Issue:
unknown, P. 137601 - 137601
Published: March 1, 2025
Language: Английский
Engineering an Ionic Aggregation-Induced Luminescence-Labeled Fluorescence Lateral Flow Immunoassay for C-Reactive Protein in Human Plasma
Pei-Yuan Sun,
No information about this author
Q. Li,
No information about this author
Ning Gao
No information about this author
et al.
Analytical Chemistry,
Journal Year:
2024,
Volume and Issue:
97(1), P. 565 - 573
Published: Dec. 27, 2024
The
surge
of
lateral
flow
immunoassays
(LFAs)
stimulates
researchers
to
explore
the
novel
vibrant
aggregation-induced
emission
luminogen
(AIEgen)-doped
nanoparticles
improve
accuracy
and
reliability
LFAs.
However,
loading
amount
AIEgens
currently
used
for
LFA
in
microspheres
is
limited
due
their
symmetrical
large
conjugated
skeleton
structure,
which
significantly
reduces
fluorescence
brightness
signal
reporter
LFA.
Herein,
an
ionic
with
a
donor–acceptor
type
was
developed
as
C-reactive
protein
(CRP).
Ionic
are
unable
enter
hydrophobic
cavity
polystyrene
(PS)
because
low
nature.
By
altering
extended
alkyl
chains,
it
possible
increase
hydrophobicity,
thereby
potentially
increasing
capacity
within
PS.
Notably,
fluorescent
(denoted
AIETPANPs)
formed
by
embedding
(E)-4-(4-(diphenylamino)styryl)-1-octadecylpyridin-1-ium
iodide
(TPA)
PS
showed
orange-red
have
high
quantum
yield.
Anti-CRP
antibody
(mAb1)
could
be
effectively
surface
AIETPANPs
amino-carboxyl
reaction,
resulting
AIETPANPs-mAb1.
AIETPANPs-mAb1
exhibited
at
613
nm,
point
detectable
naked
eye
minimal
background
interference.
entire
analysis
accomplished
just
10
min,
achieving
limit
detection
4.06
ng/mL
CRP.
AIETPANPs-mAb1-based
demonstrates
excellent
stability
specificity
fully
meets
requirements
clinical
diagnosis.
Language: Английский
Lychee-shaped magneto-gold nanohybrid with highly retained magnetic-plasmonic activity for ultrasensitive and multiplex immunochromatographic assay
Yuhao Wu,
No information about this author
Xiaolong Wang,
No information about this author
Jiayi Sun
No information about this author
et al.
Chemical Engineering Journal,
Journal Year:
2024,
Volume and Issue:
unknown, P. 157262 - 157262
Published: Oct. 1, 2024
Language: Английский
Dual-Fluorescent Quantum Dot Nanobead-Based Lateral Flow Immunoassay for Simultaneous Detection of C-Reactive Protein and Procalcitonin
Xinyue Tang,
No information about this author
Wenwen Xia,
No information about this author
Huanxing Han
No information about this author
et al.
ACS Applied Bio Materials,
Journal Year:
2024,
Volume and Issue:
7(11), P. 7659 - 7665
Published: Nov. 1, 2024
Simultaneous
detection
of
C-reactive
protein
(CRP)
and
procalcitonin
(PCT)
at
the
point
care
is
crucial
for
management
infections
in
patients
with
inflammation
critical
settings.
The
challenge
detecting
high
concentrations
CRP
alongside
low
PCT
plasma
from
inflammatory
has
limited
clinical
application
multiplexed
immunoassays.
Herein,
we
developed
a
lateral
flow
immunoassay
(LFIA)
that
employs
quantum
dot
nanobeads
(QDNBs)
varying
sizes
colors
to
enable
simultaneous
quantification
human
plasma.
To
extend
dynamic
range
detection,
combined
QDNBs
smaller
particle
antibodies,
thereby
increasing
assay's
reducing
hook
effect.
At
same
time,
stronger
fluorescence
emitted
by
these
larger
QDNBs,
conjugation
allows
nanogram
level,
meeting
demand
sensitivity.
results
show
this
method
can
detect
0.1
3
mg/L
limit
0.09
ng/mL,
which
on
par
clinically
used
methods.
By
employing
dual-color
dual-size
QDNB
labeling
strategy,
successfully
achieved
broad
sensitivity
one-step
point-of-care
rapid
test.
Language: Английский