Study of novel matrix certified reference material for accurate measurement of AFM1 in milk powder with two different concentrations DOI Creative Commons
Chun-Yuan Huang, Yaxuan Liu, Jian Zhou

et al.

Research Square (Research Square), Journal Year: 2023, Volume and Issue: unknown

Published: Aug. 18, 2023

Abstract In this study, two different concentrations of matrix certified reference materials (CRMs) were produced for the accurate measurement aflatoxin M1(AFM1) in milk powder((GBW(E) 100552, GBW(E) 100553)). The raw material was obtained by feeding cows with positive drugs. homogeneity, stability and characterization CRMs examined liquid chromatography tandem mass spectrometry isotope-labeled internal standard method. value low concentration AFM1 powder 2.45 µg/kg an uncertainty 0.43 (coverage factor k = 2, at 95% confidence). high 3.45 expanded 0.49 addition, samples evaluated detail long-term -80°C 6 months, short-term 4°C 7 days. results showed that stable under above conditions.

Language: Английский

Lateral Flow Immunosensing of Salmonella Typhimurium Cells in Milk: Comparing Three Sequences of Interactions DOI Creative Commons
Nadezhda A. Byzova, Irina V. Safenkova, A. A. Gorbatov

et al.

Microorganisms, Journal Year: 2024, Volume and Issue: 12(12), P. 2555 - 2555

Published: Dec. 11, 2024

To ensure the safety of foodstuffs, widespread non-laboratory monitoring for pathogenic contaminants is in demand. A suitable technique this purpose lateral flow immunoassay (LFIA) which combines simplicity, rapidity, and productivity with specific immune detection. This study considered three developed formats LFIA Salmonella Typhimurium, a priority contaminant milk. Common sandwich all immunoreagents pre-applied to test strip (format A) was compared incubation sample (gold nanoparticle—antibody) conjugate, preceding processes B), sequential passages conjugate along C). Under chosen conditions, detection limits assay times were 3 × 104, 1 105, 105 cells/mL, 10, 15, 20 min A, B, C, respectively. The selected format successfully applied milk samples. sample’s dilution fat content 1.0% causes pathogen detection, 70–110% revealing 1.5–8.5% accuracy. obtained results demonstrate that allows lower concentrations cells and, way, accelerates decision-making food control.

Language: Английский

Citations

0

Introduction of a multilayered fluorescent nanofilm into lateral flow immunoassay for ultrasensitive detection of Salmonella typhimurium in food samples DOI

Qing Yu,

Xuan Xia,

Changyue Xu

et al.

Analytical Methods, Journal Year: 2023, Volume and Issue: 15(30), P. 3631 - 3641

Published: Jan. 1, 2023

An ultrasensitive LFIA based on multilayered fluorescent nanofilm-guided signal amplification was developed for the rapid and quantitative determination of Salmonella typhimurium in complex food samples.

Language: Английский

Citations

0

Study of novel matrix certified reference material for accurate measurement of AFM1 in milk powder with two different concentrations DOI Creative Commons
Chun-Yuan Huang, Yaxuan Liu, Jian Zhou

et al.

Research Square (Research Square), Journal Year: 2023, Volume and Issue: unknown

Published: Aug. 18, 2023

Abstract In this study, two different concentrations of matrix certified reference materials (CRMs) were produced for the accurate measurement aflatoxin M1(AFM1) in milk powder((GBW(E) 100552, GBW(E) 100553)). The raw material was obtained by feeding cows with positive drugs. homogeneity, stability and characterization CRMs examined liquid chromatography tandem mass spectrometry isotope-labeled internal standard method. value low concentration AFM1 powder 2.45 µg/kg an uncertainty 0.43 (coverage factor k = 2, at 95% confidence). high 3.45 expanded 0.49 addition, samples evaluated detail long-term -80°C 6 months, short-term 4°C 7 days. results showed that stable under above conditions.

Language: Английский

Citations

0