Solid-State Microfabricated Potentiometric Sensors for Selective Assessment of Diclofenac Sodium Utilizing Pentafluorophenyl Diazonium Modified Carbon Nanotubes Transducer Layer DOI Creative Commons
Iman Sami,

Hany Bebawi,

Amr M. Mahmoud

et al.

Journal of The Electrochemical Society, Journal Year: 2024, Volume and Issue: 171(7), P. 077505 - 077505

Published: July 1, 2024

In the pharmaceutical field, analytical chemistry is evolving and one area that experiencing enthusiasm design implementation of solid contact ion-selective electrodes. We have developed two potentiometric sensors for selective assay a widely used drug diclofenac sodium. Diclofenac sodium was targeted in its most recommended dosage forms (Arthrotec ® tablets) presence misoprostol. A cost-effective copper printed circuit board as substrate has been coated with PVC sensing membrane to fabricate sensor I. Hydrophobic carbon nanotubes (CNTs) modified through situ reduction pentafluorophenyl diazonium using borohydride. An interlayer CNTs inserted transducer layer between Cu ion-sensing II enhance electrochemical performance stability. The microfabricated electrodes demonstrated encouraging outcomes upon direct combination misoprostol other additives without sample preparation steps. responses presented linear Nernstian pattern range 1.0 × 10 −4 −2 mol l −1 slope −58.2 −58.4 mV/decade I II, consequently. Finally, sustainability technique assured advanced green metrics.

Language: Английский

Novel Green Chromatographic Approaches for Estimation of a Triple Common Cold Pharmaceutical Combination DOI

Rabab M. Soliman,

Yasmin Rostom,

Yasmin M. Fayez

et al.

Journal of Chromatographic Science, Journal Year: 2024, Volume and Issue: unknown

Published: Sept. 26, 2024

Abstract Nowadays, there is a strong interest in the scientific community developing innovative methodologies within green analytical chemistry framework. Herein, we introduce first chromatographic approaches for concurrent estimation of paracetamol (PAR), carbinoxamine (CRX), and pseudoephedrine (PSE) intended to relieve COVID-19 common cold symptoms. The method was thin layer chromatography (TLC) densitometry, which depends on separation studied medications TLC silica gel plates using ethyl acetate: methanol: ammonia (7.0: 3.0: 0.2, by volume) as system, were scanned at 208.0 nm. data linear ranges 1–25 μg/band PAR, PSE 0.1–5 CRX. second reversed-phase high-performance liquid Kromasil C18 column mixture 0.01 M phosphate buffer containing 0.1% triethylamine (pH 3.5) adjusted with orthophosphoric acid ethanol flow rate 1.0 mL/min gradient program. separated peaks detected 215.0 nm over concentration range 10–250 μg/mL 5–35 PSE, 0.5–25 Both validated according International Conference Harmonization (ICH) guidelines. Finally, impact these methods environment evaluated many tools.

Language: Английский

Citations

1

Solid-State Microfabricated Potentiometric Sensors for Selective Assessment of Diclofenac Sodium Utilizing Pentafluorophenyl Diazonium Modified Carbon Nanotubes Transducer Layer DOI Creative Commons
Iman Sami,

Hany Bebawi,

Amr M. Mahmoud

et al.

Journal of The Electrochemical Society, Journal Year: 2024, Volume and Issue: 171(7), P. 077505 - 077505

Published: July 1, 2024

In the pharmaceutical field, analytical chemistry is evolving and one area that experiencing enthusiasm design implementation of solid contact ion-selective electrodes. We have developed two potentiometric sensors for selective assay a widely used drug diclofenac sodium. Diclofenac sodium was targeted in its most recommended dosage forms (Arthrotec ® tablets) presence misoprostol. A cost-effective copper printed circuit board as substrate has been coated with PVC sensing membrane to fabricate sensor I. Hydrophobic carbon nanotubes (CNTs) modified through situ reduction pentafluorophenyl diazonium using borohydride. An interlayer CNTs inserted transducer layer between Cu ion-sensing II enhance electrochemical performance stability. The microfabricated electrodes demonstrated encouraging outcomes upon direct combination misoprostol other additives without sample preparation steps. responses presented linear Nernstian pattern range 1.0 × 10 −4 −2 mol l −1 slope −58.2 −58.4 mV/decade I II, consequently. Finally, sustainability technique assured advanced green metrics.

Language: Английский

Citations

0