3D Composite SERS Substrate Constructed by Au-Ag core-satellite NPs and Polystyrene Sphere for Ultrasensitive Ratiometric Raman Detection of Cotinine
Gaofeng Wu,
No information about this author
Jian Zhu,
No information about this author
Guojun Weng
No information about this author
et al.
Talanta,
Journal Year:
2025,
Volume and Issue:
289, P. 127742 - 127742
Published: Feb. 14, 2025
Language: Английский
Celiac disease biomarker quantification in human fluid microenvironment: A selective and ultrasensitive magnetosensing immunoplatform
Sensors and Actuators B Chemical,
Journal Year:
2025,
Volume and Issue:
unknown, P. 137504 - 137504
Published: Feb. 1, 2025
Language: Английский
Early and sensitive diagnosis of celiac autoimmune disease by using carboxylic acid functionalized magnetic nanoparticles-assisted biosensing platform
Microchimica Acta,
Journal Year:
2025,
Volume and Issue:
192(5)
Published: April 8, 2025
Abstract
A
novel
impedimetric
magneto-immunosensor
based
on
iron
oxide
(Fe
3
O
4
)
nanoparticles
coated
with
3-phosphonopropionic
acid
(3-PPA)
(functionalized
magnetic
beads,
or
FMBs)
was
created
for
the
highly
sensitive
and
selective
detection
of
anti-tissue
transglutaminase
antibody
(anti-tTG)
in
human
serum.
This
label-less
immunosensor
introduced
by
magnetically
attaching
FMBs
onto
working
electrode
surface
a
neodium
magnet.
The
were
utilized
as
sensing
interface
had
carboxylic
groups
tTG
molecules,
which
could
selectively
link
target
anti-tTG
antibody.
modification
steps
carried
out
microcentrifuge
tubes
concentrated
force
before
electrochemical
analyses.
specific
immuno-interactions
characterized
using
microscopic
techniques,
presence
antibodies,
they
captured
tTG-immobilized
significant
increases
observed
response.
magneto
biosensor
response
linearly
related
to
level
broad
linear
range
0.125–15.62
U/mL
low
limit
(LOD)
0.04
U/mL.
Additionally,
this
sensor
stable,
repeatable,
reproducible,
selective,
determination
anti-tTG.
commercial
enzyme-linked
immunosorbent
assay
(ELISA)
method
employed
compare
responses
suggested
actual
samples.
results
good
agreement
ELISA
reference
technique
results.
Consequently,
performance
analysis
serum
samples
acceptable.
Graphical
Language: Английский
Fabrication of a highly sensitive conductive copolymer layer modified immunosensing tool for cytokeratin-19 fragment detection
Microchemical Journal,
Journal Year:
2024,
Volume and Issue:
206, P. 111464 - 111464
Published: Aug. 23, 2024
Language: Английский
Real-Time and Ultrasensitive Prostate-Specific Antigen Sensing Using Love-Mode Surface Acoustic Wave Immunosensor Based on MoS2@Cu2O-Au Nanocomposites
Yan Yu,
No information about this author
Haiyu Xie,
No information about this author
Tao Zhou
No information about this author
et al.
Sensors,
Journal Year:
2024,
Volume and Issue:
24(23), P. 7636 - 7636
Published: Nov. 29, 2024
Prostate-specific
antigen
(PSA)
is
a
well-established
tumour
marker
for
prostatic
carcinoma.
In
this
study,
we
present
novel,
real-time,
and
ultrasensitive
Love-mode
surface
acoustic
wave
(L-SAW)
immunosensor
PSA
detection
enhanced
by
MoS
Language: Английский