Microchemical Journal, Journal Year: 2024, Volume and Issue: unknown, P. 112618 - 112618
Published: Dec. 1, 2024
Language: Английский
Microchemical Journal, Journal Year: 2024, Volume and Issue: unknown, P. 112618 - 112618
Published: Dec. 1, 2024
Language: Английский
Microchemical Journal, Journal Year: 2024, Volume and Issue: 201, P. 110645 - 110645
Published: April 27, 2024
Language: Английский
Citations
16Journal of Fluorescence, Journal Year: 2024, Volume and Issue: unknown
Published: May 1, 2024
Language: Английский
Citations
16Microchimica Acta, Journal Year: 2024, Volume and Issue: 191(8)
Published: Aug. 1, 2024
Language: Английский
Citations
12Microchemical Journal, Journal Year: 2024, Volume and Issue: 204, P. 111092 - 111092
Published: June 29, 2024
Language: Английский
Citations
11Microchemical Journal, Journal Year: 2024, Volume and Issue: 204, P. 111129 - 111129
Published: July 5, 2024
Language: Английский
Citations
10Microchemical Journal, Journal Year: 2025, Volume and Issue: unknown, P. 112789 - 112789
Published: Jan. 1, 2025
Language: Английский
Citations
1RSC Advances, Journal Year: 2025, Volume and Issue: 15(9), P. 6962 - 6973
Published: Jan. 1, 2025
The leaching of aluminum and cobalt ions into canned foods, such as from tomato sauce tuna, raises concerns about potential health risks, making their accurate detection essential for food safety. In this study, we developed a novel ratiometric fluorometric sensor based on dual-emission carbon dots capable selectively detecting (Al3+) (Co2+) after single excitation. exhibits distinct fluorescence responses: enhance the emission at 403 nm due to interactions with nitrogen sulfur groups dot surface, while Al3+ 532 through binding oxygen-rich carboxyl hydroxyl. This differential response stems varying affinities these metal different functional groups, confirmed mechanistic studies comprehensive characterization dots, including TEM, UV-Vis, FTIR, lifetime analyses. method demonstrates excellent sensitivity, limits (LOD) 0.012 μM Co2+ 0.06 Al3+. sensor's performance was validated real samples, successfully determining in tuna. exhibited high selectivity minimal interference, achieving recovery rates 97.50-100.67% 97.01-98.02% Co2+. These findings underscore robustness practical applicability proposed reliable tool monitoring ensuring safety compliance regulatory standards.
Language: Английский
Citations
1Analytical Methods, Journal Year: 2024, Volume and Issue: 16(20), P. 3287 - 3296
Published: Jan. 1, 2024
Simultaneous determination of topotecan and pantoprazole.
Language: Английский
Citations
8Food Chemistry, Journal Year: 2024, Volume and Issue: 463, P. 141396 - 141396
Published: Sept. 23, 2024
Language: Английский
Citations
8Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy, Journal Year: 2024, Volume and Issue: 325, P. 125161 - 125161
Published: Sept. 19, 2024
Language: Английский
Citations
6